⇒Holding the MODE button down
until the last bar disappears
executes long-press process
(Switching between Normal
mode and Review mode, or
finalizing the parameter setting,
etc.). If turned OFF (releasing
the MODE button) before the
last bar disappears, the same
operation as ①Normal operation
will take place.
OPERATING CONDITIONS
PRECAUTIONS ON INSTALLATION LOCATION
②Analog Pulse output type
←max. 20mA
DC
←max. 20mA
max.
max. 30V
30V
←max. 20mA
DC
←max. 20mA
max.
max. 30V
30V
Output type
Specification
Factored pulse
Unfactored pulse
Analog
Model
mm
※3
L/h
L/P
Hz
mL/P
Hz
LS5277
20
1
0.33
9.918
33.6
1200
LS5377
25
1
17.955
55.7
3600
LS5577
40
10
0.20
35.496
56.3
7200
LS5677
50
10
0.33
76.455
43.6
12000
LS4976
20
1
0.22
5.928
37.5
800
LS5076
20
1
0.56
9.912
56.0
2000
LS5276
25
1
1.05
9.639
3800
LS5376
40
1
1.77
17.47
101.8
6400
LS5576
40
10
0.38
34.526
112.6 14000
LS5676
50
10
0.66
74.483
89.5
24000
Item
Specification
Local display
function
Display mode
Display mode symbol
Selectable with MODE button
Zero resettable with RESET button
①Accumulated total (8-digit)
None
②Instantaneous flow rate, L/h (5-digit)
b1
③Instantaneous flow rate, L/m (5-digit)
b2
④Resettable total (7-digit)
C
Display accuracy
Total flow
Within ±1 count
Instantaneous flow rate
Within ±1% of full scale
Display orientation
Flow detection
Magnetic sensor detects alternating magnetic fields. (200Hz max.)
Cable
Transmission
distance
Either Pulse or Analog
output used
Max. 1km
(CVVS: 1.25 to 2.0mm
2
)
Pulse + Analog output
both used
Max. 100m
(CVVS: 1.25 to 2.0mm
2
)
Power source
Lithium
battery
External
power source
12 to 50VDC±10% (consumption current: Max. 30mA)
(For analog output, refer to "6. Acceptable load resistance range")
Ambient temperature
-10 to +60℃ (no condensing)
Material
Polycarbonate (black)
Configuration
IP65 (Install indoors or under the eaves. Avoid exposure to direct sunlight.)
Left back: MODE button
Right back: RESET button
PUSH!
※1:About the display during MODE button operation
①Normal operation
②Long-press operation
Accumulated total
Instant flow rate: L/h
Instant flow rate: L/m
Resettable total
MODE
MODE
MODE
MODE
RESET
Item
Description
Pon
Factored pulse width [ms] setting
Pu
Factored pulse weight [L/P] setting
AF
Analog output full scale [L/h] setting
(Flow indicator display is linked to this setting.)
AdAn
Analog output damping [sec.] setting
LooPtESt Simulated output at arbitrary flow rate
⇒Refer to the corresponding sections in the instruction
manual for the procedures such as changing each
parameter and operating the simulated output function
.
[NOTE]
Please read before installation and use
To maintain high accuracy and long life of this meter, it is necessary that the meter
be used within the specified conditions in flow rate, pressure, temperature and
viscosity. These operating conditions are stated on the nameplate of the register.
Confirm the contents of the nameplate thoroughly before installation and operation.
(1) In this register, a magnetic sensor is used to pick up magnetic fields of signaling
magnets embedded in the rotor. For this reason, the FLOWPET should be
installed sufficiently away from sources generating magnetic field. If a magnetic
valve of 10 watts or so is used, separate it at least 10 centimeters from the
flowmeter (varies with operating conditions).
(2) For applications in cold regions, install the meter indoors (boiler room, for
example) to prevent accidents caused by freezing.
①A vertical run is recommended for ease of pipeline drainage. Provide a drain
plug.
②When installing lagging, do not lag the electronic register, strainer cover, and
drain plug. Also, make sure of ready separation of the meter from the piping
assembly. NOTE: Refer to the corresponding sections in the instruction
manual for piping details.
(3) This register operates at the temperature range of -10 to +60゜
C. To ensure its
operation within the specified temperature range, protect the register with a
sunshade or heat shield if exposure to elevated temperatures by direct sunlight,
reflected heat, etc., is expected.
(4) This register is designed for indoor use: install the meter in a location free from
rainwater, oil, or sunlight. If exposure to such environment is unavoidable,
provide appropriate weather protection or sunshade.
All specifications in this startup guide are subject to change without
notice for improvement in performance and product quality.
Electronic Register STARTUP GUIDE
Thank you for choosing the FLOWPET-5G.
・This Startup Guide provides basic information that is
helpful for starting the use of the FLOWPET-5G electronic
register. For detailed explanation of the FLOWPET-5G's
functions and operation instructions, refer to the accompa-
nying instruction manual before use.
・Please keep this Startup Guide handy for quick reference.
1.GENERAL SPECIFICATIONS
Display angle adjustable in 15°steps
(Adjust the angle up or down by hand to find
easy-to-view position)
3.BASIC OPERATION PROCEDURE (MEASURE MODE)
The flow indicator at the bottom of the display indicates % of actual flow
(instantaneous flow rate) to the full scale flow rate.
NOTE: Full scale flow rate (flow rate which represents 100%) is determined in
the parameter: AF. (AF value is also applied to the analog output full scale value
of analog output specification)
On the resettable total display,
zero-reset will be performed on
total flow by pressing the RESET
button.
When the MODE button is
pressed:
⇒8 bars appear.
When the MODE button is
kept pressed down:
⇒Bars begin to disappear
one by one from the left
⇒Immediately turning OFF
(letting go of the button)
scrolls the display to the
next one.
2.OPERATION BUTTONS
・The push buttons for operation (MODE and RESET) are located
on the back of the display.
BRO SUP.: Power +
BRO SUP.: Power +
4.WIRING (for models with output capability)
①Pulse output type
GRY SIG.1: Factored pulse (or Alarm 1)
※1
GRY SIG.1: Factored pulse (or Alarm 1)
※1
WHI SIG.2: Unfactored pulse (or Alarm 2)
※1
WHI SIG.2: Unfactored pulse (or Alarm 2)
※1
12 to 50V
12 to 50V
GRN COM: 0V
GRN COM: 0V
NOTE: Leave the shielded wire open at its end (no contact). To extend the
cable, make sure to use shielded wire and extend the shield as well.
NOTE: Leave the shielded wire open at its end (no contact). To extend the
cable, make sure to use shielded wire and extend the shield as well.
4 to 20mA Analog output
※1: SIG.1 and SIG.2 can generate pulses by built-in battery power without external power source.(Battery life is 8 years approximately.)
For analog output only model, leave the ends of SIG.1 and SIG.2 cables open since they will not be used. Alarm output is optional.
8.DISPLAY MENU TREE
5.OUTPUT SPECIFICATIONS
・Open drain output (equivalent of open collector)
・Allowable current: 20mA, Max. voltage applied: 30V
(Adjustable at [Pon] parameter within the range of 1 to 999ms in 1ms increments.)
・Open drain output (equivalent of open collector)
・Allowable current: 20mA, Max. voltage applied: 30V ・Pulse width: 2ms (fixed)
・4 to 20mA output (using power wire) ・Acceptable load resistance: see figure below.
6.
ACCEPTABLE LOAD RESISTANCE RANGE 7.STANDARD PULSE UNIT
※2
1.00
109.5
※2: Unless otherwise specified, pulse unit is set according to factored pulse unit listed in the above table. For the official
specification at the time of shipment, please confirm the nameplate on the actual product.
※3: Full scale values of "Flow indicator display" and "Analog output" will be max. flow rate values in the table above.
(For oil-service models, the actual rated maximum flow rate varies by types of oil.)
Under "Review Mode", setting changes to the items listed
below and using special functions such as "Simulated
Output" are available.
1900
600
0
12
24
50
Power supply voltage (VDC)
PRESS
PRESS
to turn on
to turn on
PRESS
to turn on
XXXXXXXX [□]
b1±XXXXX [□/h]
b2±XXXXX [□/min]
CXXXXXXX [□]
totAL
Alarm data
A
.tri.
tESt
Simulated output
Service mode
F
Instant flow related data
d
Alarm 1 setting
Simulated instant flow value
Simulated total flow value
Input frequency display
H
n
Full scale flow rate
H
Alarm 1 hysteresis
Operating time
Pu
Damping
Instant flow decimal point
S
Alarm 1 status
Simulated output
Flow operating time
Pulse width
Sampling time
d
Indicated unit
H
Alarm 2 hysteresis
Total flow decimal point
S
Alarm 2 status
None
C
:Holding the MODE switch pressed for more than 2 seconds at this
display changes the Review Mode to the Write Mode. The following
operations are enabled in the Write Mode:
①Pressing the MODE switch moves the digit one place to the left.
②Pressing the RESET switch increases the figure by one.
③Holding the MODE switch pressed for more than 2 seconds again
changes the mode back to the Review Mode.
:Title
(Titles describe the attributes of each parameter stored under each
title: They are not settable parameters.)
:Switching to Write Mode from these displays will allow operators to
use special functions such as analog trims and simulated output.
NOTE: Goes back to the screen before
switching to Review Mode
:Transition made by pressing "MODE" switch
:Transition made by keeping "MODE" switch pressed for more than 5 seconds
:Transition made by pressing "RESET" switch
b1
b2
Accumulated total
Instant flow rate (hourly)
Instant flow rate (per-minute)
Resettable total
Total flow related data
Meter factor
Conversion factor
Digital output 1 assign.
Digital output 2 assign.
Sampling cycle number
Alarm 2 setting
NOTE: Displayed only on analog
output equipped models.
Analog trim
4mA trim
20mA trim
No. of MODE switch press
No. of RESET switch press
Factory reset
Software revision
NOTE: Not displayed on standard
specification. (Displayed only on
alarm option specified models)
※1: During Review Mode, the information icon is
displayed on the upper right corner of the screen.
※2: Parameter symbols are displayed at flow rate unit display
area.
※3: This product does not use d.o3 mode setting.
Ins. No. S-179-SU-1-E
Operating
range
1m of vinyl-sheathed, 4-conductor shielded cable (individual elements AWG24)
furnished as standard (Not furnished with models without pulse generator)
3.6VDC dedicated battery built-in, Battery life: 8 years (varies with operating conditions)
Storage life: 10 years
・Battery icon blinks as the battery starts to run out.
・If equipped with pulse output capability, pulse generation can be done just with built- in
battery without an external power source. (If supplied with external power source, lithium
battery will not be consumed.)
Each time the MODE button is pressed, the screen scrolls through
flow displays; select the desired flow display.
(Accumulated total → Instantaneous flow: L/h → Instantaneous flow:
L/m → Resettable total)
Load resistance: R
L
All parameters are set before shipment based on the
specifications at the time of order receipt, and generally
there is no need for the users to perform parameter
setting. Proper flow measurement may be unavailable if
parameter setting is performed inappropriately. Please
avoid performing unnecessary changes to the param-
eters. (Confirm the corresponding sections in the instruc-
tion manual thoroughly in case it is necessary to make
parameter changes.)
Factored
pulse
Unfactored
pulse
Max.
flow rate
Nom.
size
Pulse
unit
Output
freq.
Nominal
meter
factor
Output
freq.
Load resistance
R
L
(Ω)
Measur
e
Mode
(
nor
m
a
l
m
ode
)
Re
v
ie
w
M
ode
Pulse weight
OVAL Corporation
Phone. 81-3-3360-5121 Fax. 81-3-3365-8605
FLOWPET-5G
StArt
A20
A04
※3
※1
※2
※2
d.o3
Digital output 3 assign.
Energy Savemode setting
ES.bt.