OPERATING CONDITIONS

PRECAUTIONS ON INSTALLATION LOCATION

                                     

                                                   

                                                                                                                             

②Analog  Pulse output type

 

←max. 20mA

          DC

                 

                                    ←max. 20mA

                      max.

                                                                      max.      30V

              30V         

   

                                    ←max. 20mA

            DC

                   

                                    ←max. 20mA   

                  max.

            max.      30V

              30V         

Output type

Specification

Factored pulse

Unfactored pulse

Analog

 

Model

mm

※3

L/h

L/P

Hz

mL/P

Hz

LS5277

20

1

0.33

9.918

33.6

1200

LS5377

25

1

17.955

55.7

3600

LS5577

40

10

0.20

35.496

56.3

7200

LS5677

50

10

0.33

76.455

43.6

12000

LS4976

20

1

0.22

5.928

37.5

800

LS5076

20

1

0.56

9.912

56.0

2000

LS5276

25

1

1.05

9.639

3800

LS5376

40

1

1.77

17.47

101.8

6400

LS5576

40

10

0.38

34.526

112.6 14000

LS5676

50

10

0.66

74.483

89.5

24000

Item

Specification

Local display 

function

Display mode

Display mode symbol

Selectable with MODE button

Zero resettable with RESET button

①Accumulated total (8-digit)

None

②Instantaneous flow rate, L/h (5-digit)

b1

③Instantaneous flow rate, L/m (5-digit)

b2

④Resettable total (7-digit)

Display accuracy

Total flow

Within ±1 count

Instantaneous flow rate

Within ±1% of full scale

Display orientation

Flow detection

Magnetic sensor detects alternating magnetic fields. (200Hz max.)

Cable

Transmission 

distance

Either Pulse or Analog 
output used

Max. 1km
(CVVS: 1.25 to 2.0mm

2

)

Pulse + Analog output 
both used

Max. 100m
(CVVS: 1.25 to 2.0mm

2

)

Power source

Lithium 

battery

External 

power source

12 to 50VDC±10% (consumption current: Max. 30mA)
(For analog output, refer to "6. Acceptable load resistance range")               

Ambient temperature

-10 to +60℃ (no condensing)

Material

Polycarbonate (black)

Configuration

IP65 (Install indoors or under the eaves. Avoid exposure to direct sunlight.) 

Left back: MODE button

        

Right back: RESET button

PUSH!

※1:About the display during MODE button operation

①Normal operation

②Long-press operation

Accumulated total

Instant flow rate: L/h

Instant flow rate: L/m

Resettable total

MODE

MODE

MODE

MODE

RESET

Item

Description

Pon

Factored pulse width [ms] setting

Pu

Factored pulse weight [L/P] setting

AF

Analog output full scale [L/h] setting
(Flow indicator display is linked to this setting.)

AdAn

Analog output damping [sec.] setting

LooPtESt Simulated output at arbitrary flow rate

⇒Refer to the corresponding sections in the instruction 
   manual for the procedures such as changing each 
   parameter and operating the simulated output function

.

[NOTE]

   

Please read before installation and use

To maintain high accuracy and long life of this meter, it is necessary that the meter 
be  used  within  the  specified  conditions  in  flow  rate,  pressure,  temperature  and 
viscosity. These operating conditions are stated on the nameplate of the register. 
Confirm the contents of the nameplate thoroughly before installation and operation.

(1) In this register, a magnetic sensor is used to pick up magnetic fields of signaling 

magnets  embedded  in  the  rotor.  For  this  reason,  the  FLOWPET  should  be 
installed sufficiently away from sources generating magnetic field. If a magnetic 
valve  of  10  watts  or  so  is  used,  separate  it  at  least  10  centimeters  from  the 
flowmeter (varies with operating conditions).

(2)  For  applications  in  cold  regions,  install  the  meter  indoors  (boiler  room,  for 

example) to prevent accidents caused by freezing.

  ①A vertical run is recommended for ease of pipeline drainage. Provide a drain 

 plug.

  ②When installing lagging, do not lag the electronic register, strainer cover, and 

 drain plug. Also, make sure of ready separation of the meter from the piping 
 assembly. NOTE: Refer to the corresponding sections in the instruction 
 manual for piping details.

(3) This register operates at the temperature range of -10 to +60゜

C. To ensure its 

operation  within  the  specified  temperature  range,  protect  the  register  with  a 
sunshade or heat shield if exposure to elevated temperatures by direct sunlight, 
reflected heat, etc., is expected. 

(4) This register is designed for indoor use: install the meter in a location free from 

rainwater,  oil,  or  sunlight.  If  exposure  to  such  environment  is  unavoidable, 
provide appropriate weather protection or sunshade.

All specifications in this startup guide are subject to change without 
notice for improvement in performance and product quality.

Electronic Register STARTUP GUIDE

Thank you for choosing the FLOWPET-5G.

・This  Startup  Guide  provides  basic  information  that  is 

helpful for starting the use of the FLOWPET-5G electronic 
register.  For  detailed  explanation  of  the  FLOWPET-5G's 
functions and operation instructions, refer to the accompa-
nying instruction manual before use.

・Please keep this Startup Guide handy for quick reference.

1.GENERAL SPECIFICATIONS  

Display angle adjustable in 15°steps
(Adjust the angle up or down by hand to find 
 easy-to-view position)

3.BASIC OPERATION PROCEDURE (MEASURE MODE)

The flow indicator at the bottom of the display indicates % of actual flow 
(instantaneous flow rate) to the full scale flow rate.
NOTE: Full scale flow rate (flow rate which represents 100%) is determined in 
the parameter: AF. (AF value is also applied to the analog output full scale value 
of analog output specification)

On the resettable total display, 
zero-reset will be performed on 
total flow by pressing the RESET 
button.

When the MODE button is 
pressed:
⇒8 bars appear.

When the MODE button is 

kept pressed down:

⇒Bars begin to disappear

   one by one from the left 

⇒Immediately  turning  OFF  

(letting  go  of  the  button) 
scrolls  the  display  to  the 
next one.

2.OPERATION BUTTONS

・The push buttons for operation (MODE and RESET) are located 

on the back of the display.

BRO SUP.: Power +

BRO SUP.: Power +

4.WIRING (for models with output capability)

①Pulse output type

GRY SIG.1: Factored pulse (or Alarm 1)

※1

GRY SIG.1: Factored pulse (or Alarm 1)

※1

WHI SIG.2: Unfactored pulse (or Alarm 2)

※1

WHI SIG.2: Unfactored pulse (or Alarm 2)

※1

12 to 50V

12 to 50V

GRN COM: 0V

GRN COM: 0V

NOTE: Leave the shielded wire open at its end (no contact). To extend the
          cable, make sure to use shielded wire and extend the shield as well.

NOTE: Leave the shielded wire open at its end (no contact). To extend the
          cable, make sure to use shielded wire and extend the shield as well.

4 to 20mA Analog output

※1: SIG.1 and SIG.2 can generate pulses by built-in battery power without external power source.(Battery life is 8 years approximately.)
       For analog output only model, leave the ends of SIG.1 and SIG.2 cables open since they will not be used. Alarm output is optional.

8.DISPLAY MENU TREE

5.OUTPUT SPECIFICATIONS

・Open drain output (equivalent of open collector)
・Allowable current: 20mA, Max. voltage applied: 30V
 (Adjustable at [Pon] parameter within the range of 1 to 999ms in 1ms increments.)
   

・Open drain output (equivalent of open collector)  
・Allowable current: 20mA, Max. voltage applied: 30V  ・Pulse width: 2ms (fixed)

・4 to 20mA output (using power wire)  ・Acceptable load resistance: see figure below.

  6.

ACCEPTABLE LOAD RESISTANCE RANGE     7.STANDARD PULSE UNIT

※2

1.00

109.5

※2: Unless otherwise specified, pulse unit is set according to factored pulse unit listed in the above table. For the official 
   specification at the time of shipment, please confirm the nameplate on the actual product.
※3: Full scale values of "Flow indicator display" and "Analog output" will be max. flow rate values in the table above. 
      (For oil-service models, the actual rated maximum flow rate varies by types of oil.)

Under "Review Mode", setting changes to the items listed 
below and using special functions such as "Simulated 
Output" are available.

1900

600

0

12

24

50

Power supply voltage (VDC)

PRESS

PRESS

to turn on

to turn on

PRESS

to turn on

 
 

XXXXXXXX [□]

 
 

   

 

b1±XXXXX [□/h]

b2±XXXXX [□/min]

CXXXXXXX [□]

totAL

Alarm data

A

.tri. 

tESt

Simulated output

Service mode

F

Instant flow related data

d

Alarm 1 setting

Simulated instant flow value

Simulated total flow value

Input frequency display

H

n

Full scale flow rate

H

Alarm 1 hysteresis

Operating time

Pu

Damping

Instant flow decimal point

S

Alarm 1 status

Simulated output

Flow operating time

Pulse width

Sampling time

d

Indicated unit

H

Alarm 2 hysteresis

Total flow decimal point

S

Alarm 2 status

None

C

:Holding the MODE switch pressed for more than 2 seconds at this         
 display changes the Review Mode to the Write Mode. The following 
   operations are enabled in the Write Mode:
  ①Pressing the MODE switch moves the digit one place to the left.
  ②Pressing the RESET switch increases the figure by one.
  ③Holding the MODE switch pressed for more than 2 seconds again
     changes the mode back to the Review Mode.

:Title
  (Titles describe the attributes of each parameter stored under each 
  title: They are not settable parameters.)

:Switching to Write Mode from these displays will allow operators to 
   use special functions such as analog trims and simulated output.

NOTE: Goes back to the screen before 
           switching to Review Mode

:Transition made by pressing "MODE" switch
:Transition made by keeping "MODE" switch pressed for more than 5 seconds
:Transition made by pressing "RESET" switch

b1

b2

Accumulated total

Instant flow rate (hourly)

Instant flow rate (per-minute)

Resettable total

Total flow related data

Meter factor

Conversion factor

Digital output 1 assign.

Digital output 2 assign.

Sampling cycle number

Alarm 2 setting

  NOTE: Displayed only on analog 
                 output equipped models.

Analog trim

4mA trim

20mA trim

No. of MODE switch press

No. of RESET switch press

Factory reset

Software revision

    NOTE: Not displayed on standard 
               specification. (Displayed only on 
               alarm option specified models)

※1: During Review Mode, the information icon     is 

       displayed on the upper right corner of the screen.
※2: Parameter symbols are displayed at flow rate unit display
       area.
※3: This product does not use d.o3 mode setting.

Ins. No. S-179-SU-1-E

Operating 

range

1m of vinyl-sheathed, 4-conductor shielded cable (individual elements AWG24) 
furnished as standard (Not furnished with models without pulse generator)

3.6VDC  dedicated  battery  built-in,  Battery  life:  8  years  (varies  with  operating  conditions) 

Storage life: 10 years

・Battery icon blinks as the battery starts to run out.

・If equipped with pulse output capability, pulse generation can be done just with built- in

   battery without an external power source. (If supplied with external power source, lithium

   battery will not be consumed.)

Each time the MODE button is pressed, the screen scrolls through 
flow displays; select the desired flow display.
(Accumulated total → Instantaneous flow: L/h → Instantaneous flow: 
L/m → Resettable total)

Load resistance: R

L

All  parameters  are  set  before  shipment  based  on  the 
specifications at the time of order receipt, and generally 
there  is  no  need  for  the  users  to  perform  parameter 
setting.  Proper  flow  measurement  may  be  unavailable  if 
parameter  setting  is  performed  inappropriately.  Please 
avoid  performing  unnecessary  changes  to  the  param-
eters. (Confirm the corresponding sections in the instruc-
tion  manual  thoroughly  in  case  it  is  necessary  to  make 
parameter changes.)

Factored

pulse

Unfactored

pulse

Max.

flow rate

Nom.

size

Pulse

unit

Output 

freq.

Nominal

meter

factor

Output 

freq.

Load resistance

 

R

L

(Ω)

Measur

e

 Mode

 (

nor

m

a

m

ode

)

Re

v

ie

w

 M

ode

Pulse weight

OVAL Corporation

Phone. 81-3-3360-5121   Fax. 81-3-3365-8605

FLOWPET-5G

StArt

A20

A04  

※3

※1

※2

※2

d.o3

Digital output 3 assign.

Energy Savemode setting

ES.bt.