background image

Quick Start Guide

Advanced sensor with dual digital displays for small object counting applications

For complete technical information about this product, including dimensions, accessories, and specifications, see 

http://

www.bannerengineering.com

 and search 178236.

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Overview

Figure 1. DF-G2 Model Features

1

Output LED

2

LO/DO Switch

3

RUN/PRG/ADJ Mode Switch

4

Lever Action Fiber Clamp

5

Red Signal Level

6

Green Threshold

7

+/SET/- Rocker Button

Models

Model

Outputs

Connector1

DF-G2-NC-2M

Single NPN, plus Health Mode output

2 m (6.5 ft) cable, 5-wire

DF-G2-PC-2M

Single PNP, plus Health Mode output

DF-G2-NC-Q5

Single NPN, plus Health Mode output

150 mm (6 in) PVC cable with a 5-pin M12/Euro-style quick

disconnect

DF-G2-PC-Q5

Single PNP, plus Health Mode output

DF-G2-NC-Q7

Single NPN, plus Health Mode output

Integral 5-pin M8/Pico-style quick disconnect

DF-G2-PC-Q7

Single PNP, plus Health Mode output

1 Connector options:

A model with a QD connector requires a mating cordset

For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NC-9M)

For 150 mm (6 in) PVC cable with a 5-pin M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number

(example, DF-G2-NC-Q3)

For Q3 and Q7 models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset

DF-G2 High Speed Expert

 Dual Display

Small Object Counter

 

 

Original Document

178061 Rev. E

9 September 2015

178061

Summary of Contents for DF-G2 High Speed Expert

Page 1: ...vel 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G2 NC 2M Single NPN plus Health Mode output 2 m 6 5 ft cable 5 wire DF G2 PC 2M Single PNP plus Health Mode output DF G2 NC...

Page 2: ...the DF G2 up on the DIN rail 1 3 Pivot the DF G2 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket 1 Position the DF G2 in the SA DIN BRACKET 2 Insert the supplied...

Page 3: ...nstall the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Banner includes the adapters with all fiber assemblies TO FIBERS TO SENSOR Fiber Outer Diameter m...

Page 4: ...output is ON when the sensing condition is above the threshold For Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing co...

Page 5: ...counts value to reset to 0 Program Mode or to set value or to set value or to set value display flips 180 Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY...

Page 6: ...ease decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET des...

Page 7: ...t OFF Output ON Darkest Taught Condition Lightest Taught Condition Position Figure 5 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch Troublesh...

Page 8: ...econds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear state light level see Window SET on page 6 Specifications Sensing Beam Vis...

Page 9: ...warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...