Quick Start Guide
Advanced sensor with dual digital displays for small object counting applications
and search 178236.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Overview
Figure 1. DF-G2 Model Features
1
Output LED
2
LO/DO Switch
3
RUN/PRG/ADJ Mode Switch
4
Lever Action Fiber Clamp
5
Red Signal Level
6
Green Threshold
7
+/SET/- Rocker Button
Models
Model
Outputs
Connector1
DF-G2-NC-2M
Single NPN, plus Health Mode output
2 m (6.5 ft) cable, 5-wire
DF-G2-PC-2M
Single PNP, plus Health Mode output
DF-G2-NC-Q5
Single NPN, plus Health Mode output
150 mm (6 in) PVC cable with a 5-pin M12/Euro-style quick
disconnect
DF-G2-PC-Q5
Single PNP, plus Health Mode output
DF-G2-NC-Q7
Single NPN, plus Health Mode output
Integral 5-pin M8/Pico-style quick disconnect
DF-G2-PC-Q7
Single PNP, plus Health Mode output
1 Connector options:
•
A model with a QD connector requires a mating cordset
•
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NC-9M)
•
For 150 mm (6 in) PVC cable with a 5-pin M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number
(example, DF-G2-NC-Q3)
•
For Q3 and Q7 models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset
DF-G2 High Speed Expert
™
Dual Display
Small Object Counter
Original Document
178061 Rev. E
9 September 2015
178061