background image

A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the

presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending

on the LO/DO setting.

Threshold Position

Sensor positions
threshold a programmable
 % offset below the 
presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition 
Presented

Figure 4. Light SET (Light Operate shown)

Dynamic TEACH

Teaches on-the-fly

Establishes a single switching threshold

Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual

sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the

optimum level.

Sensor positions 

threshold midway 

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

Figure 5. Dynamic TEACH (Light Operate shown)

The output ON and OFF conditions can be reversed using the LO/DO switch.

Troubleshooting

Percent Minimum Difference after TEACH

The Dynamic TEACH method will flash a % minimum difference on the displays after a PASS or FAIL.

Value

PASS/FAIL

Description

0 to 99%

FAIL

The difference of the taught conditions does not meet the required minimum

100 to 300%

PASS

The difference of the taught conditions just meets/exceeds the required minimum,

minor sensing variables may affect sensing reliability

300 to 600%

PASS

The difference of the taught conditions sufficiently exceeds the required minimum,

minor sensing variables will not affect sensing reliability

600% +

PASS

The difference of the taught conditions greatly exceeds the required minimum, very

stable operation

Percent Offset after SET

The Window and Light SET methods will flash a % offset on the displays after a PASS or FAIL.

DF-G2 High Speed Expert

 Dual Display Small Object Counter

 

 

P/N 178061 Rev. E

www.bannerengineering.com - Tel: +1-763-544-3164

7

Summary of Contents for DF-G2 High Speed Expert

Page 1: ...vel 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G2 NC 2M Single NPN plus Health Mode output 2 m 6 5 ft cable 5 wire DF G2 PC 2M Single PNP plus Health Mode output DF G2 NC...

Page 2: ...the DF G2 up on the DIN rail 1 3 Pivot the DF G2 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket 1 Position the DF G2 in the SA DIN BRACKET 2 Insert the supplied...

Page 3: ...nstall the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Banner includes the adapters with all fiber assemblies TO FIBERS TO SENSOR Fiber Outer Diameter m...

Page 4: ...output is ON when the sensing condition is above the threshold For Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing co...

Page 5: ...counts value to reset to 0 Program Mode or to set value or to set value or to set value display flips 180 Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY...

Page 6: ...ease decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET des...

Page 7: ...t OFF Output ON Darkest Taught Condition Lightest Taught Condition Position Figure 5 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch Troublesh...

Page 8: ...econds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear state light level see Window SET on page 6 Specifications Sensing Beam Vis...

Page 9: ...warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...

Reviews: