background image

Wiring Diagrams

PNP Models

Remote

Programming

(N.O.)

5

10–30 V dc

3

1

4

2

+

Health

Load

NPN Models

Remote

Programming

(N.O.)

10-30V dc

5

3

1

4

2

+

Load

Health

Key
1 = Brown

2 = White

3 = Blue

4 = Black

5 = Gray

(6 = no connection)

NOTE: Open lead wires must be connected to a terminal block.

Top Panel Interface

Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ

mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED.

 

 

RUN/PRG/ADJ Mode Switch

The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN

mode allows the sensor to operate normally and prevents unintentional programming changes via the

+/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-driven

programming menu (see Program Mode below). ADJ mode allows the user to perform Expert

TEACH/SET methods and Manual Adjust (see Adjust Mode below).

 

 

LO/DO Switch

The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output is

ON when the sensing condition is above the threshold. (For Window SET, the output is ON when the

sensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensing

condition is below the threshold. (For Window SET, the output is ON when the sensing condition is

outside the window.)

 

 

+/SET/- Rocker Button

The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/

right. The SET position is engaged by clicking down the button while the rocker is in the middle position.

All three button positions are used during PRG mode to navigate the display-driven programming menu.

During ADJ mode, SET is used to perform TEACH/SET methods. The rocker button is disabled during

RUN mode, except when using Window SET, see 

Window SET

 on page 6.

 

 

Red/Green Digital Displays

During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the

threshold or the total counts. During PRG mode, both displays are used to navigate the display-driven

programming menu.

Output LED

The output LED provides a visible indication when the output is activated.

 

 

DF-G2 High Speed Expert

 Dual Display Small Object Counter

4

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 178061 Rev. E

Summary of Contents for DF-G2 High Speed Expert

Page 1: ...vel 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G2 NC 2M Single NPN plus Health Mode output 2 m 6 5 ft cable 5 wire DF G2 PC 2M Single PNP plus Health Mode output DF G2 NC...

Page 2: ...the DF G2 up on the DIN rail 1 3 Pivot the DF G2 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket 1 Position the DF G2 in the SA DIN BRACKET 2 Insert the supplied...

Page 3: ...nstall the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Banner includes the adapters with all fiber assemblies TO FIBERS TO SENSOR Fiber Outer Diameter m...

Page 4: ...output is ON when the sensing condition is above the threshold For Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing co...

Page 5: ...counts value to reset to 0 Program Mode or to set value or to set value or to set value display flips 180 Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY...

Page 6: ...ease decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET des...

Page 7: ...t OFF Output ON Darkest Taught Condition Lightest Taught Condition Position Figure 5 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch Troublesh...

Page 8: ...econds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear state light level see Window SET on page 6 Specifications Sensing Beam Vis...

Page 9: ...warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...

Reviews: