Fiber Optic Arrays

Models 2

Detection Window

Dimensions

Fiber Exit

Minimum Object Size 3

PFCVA-10X25-S

10 mm x 25 mm

Side exit

1.5 mm

PFCVA-10X25-E

End exit

PFCVA-25X25-S

25 mm x 25 mm

Side exit

3 mm

PFCVA-25X25-E

End exit

PFCVA-34X25-S

34 mm x 25 mm

Side exit

4 mm

PFCVA-34X25-E

End exit

Installation Instructions

Mounting Instructions

Mount on a DIN Rail

1. Hook the DIN rail clip on the bottom of the DF-G2

over the edge of the DIN rail (1).

2. Push the DF-G2 up on the DIN rail (1).
3. Pivot the DF-G2 onto the DIN rail, pressing until it

snaps into place (2).

Mount to the Accessory Bracket

1. Position the DF-G2 in the SA-DIN-BRACKET.
2. Insert the supplied M3 screws.
3. Tighten the screws.

Remove from a DIN rail

1. Push the DF-G2 up on the DIN rail (1).
2. Pivot the DF-G2 away from the DIN rail and remove

it (2).

2 Custom fiber arrays and mounting configurations are possible. Consult factory for assistance with your small object counting

application.

3 With 2% threshold offset percentage

 

 

DF-G2 High Speed Expert

 Dual Display Small Object Counter

2

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 178061 Rev. E

Summary of Contents for DF-G2 High Speed Expert

Page 1: ...vel 6 Green Threshold 7 SET Rocker Button Models Model Outputs Connector1 DF G2 NC 2M Single NPN plus Health Mode output 2 m 6 5 ft cable 5 wire DF G2 PC 2M Single PNP plus Health Mode output DF G2 NC...

Page 2: ...the DF G2 up on the DIN rail 1 3 Pivot the DF G2 onto the DIN rail pressing until it snaps into place 2 Mount to the Accessory Bracket 1 Position the DF G2 in the SA DIN BRACKET 2 Insert the supplied...

Page 3: ...nstall the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Banner includes the adapters with all fiber assemblies TO FIBERS TO SENSOR Fiber Outer Diameter m...

Page 4: ...output is ON when the sensing condition is above the threshold For Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing co...

Page 5: ...counts value to reset to 0 Program Mode or to set value or to set value or to set value display flips 180 Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY...

Page 6: ...ease decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET des...

Page 7: ...t OFF Output ON Darkest Taught Condition Lightest Taught Condition Position Figure 5 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch Troublesh...

Page 8: ...econds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear state light level see Window SET on page 6 Specifications Sensing Beam Vis...

Page 9: ...warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation of the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF AL...

Reviews: