MoniMax 5100T 7. Appendix
7-
45
2. EC -> Enter Shelved Mode Combination -> OPr
Enter the current Shelved Mode combination (either 50-25-50 or a changed Shelved Mode
combination) by sequentially pressing those digits on the lock keypad. The numbers will be
displayed on the LCD as they are entered.
3. OPr -> Retract Bolt
Turn the Dial to the right (CW) to retract the bolt
4. Open Door
5. Insert Change Key
Insert the change key into the change key socket on the back of the lock.
6. Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt. Do not close the door
7. Power Lock ->
ヒ
EC
Turn the dial to the left(CCW) until
ヒ
EC (the Change Key symbol along with Enter
Combination) is displayed
8.
ヒ
EC -> Press #8 -> EcF
Press the “#” button followed by the “8” button. EcF (Enter combination, Factory) will be displayed.
9. EcF -> Enter Current Shelved Mode Combination -> EnF
Enter the current shelved mode combination, “EnF” (Enter combination, Factory) will be displayed.
10. EnF -> Enter New Combination -> Cnf
Select and enter the new combination. “CnF” (confirm new Factory combination) will be displayed
11. Cnf -> Enter New Combination -> POC
Enter new combination again to confirm. POC (Pull Out Change key) will be displayed.
12. POC -> Remove Change Key -> EOP
Remove the change key. EOP (End Operation) is displayed.
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...