MoniMax 5100T 5. Operator Function
5-27
[Touch Machine]
[No Touch Machine]
- VISA FRAMED is Executing communication using VISA flow when connecting to host using
TCPIP.
- STANDARD is Executing communication using STANDARD flow when connecting to host
using TCPIP.
- ACK CONTROLLED is Executing communication using ACK CONTROLLED when
connecting to host using TCPIP.
[NOTE]
In case of selecting “INSERVICE” on OP MAIN, if the value of TCPIP TYPE is different from
the value of EOT OPTION when entering OP, exit OP and execute reboot.
5) STANDARD OPTION #3
STANDARD OPTION #3 function is used to get the additional information when Triton
message is selected.
- STATUS MONITORING function is to decide whether status monitoring field in message is
sent or not .
- COMMUNICATION HEADER function is to decide whether communication header in
message is included or not.
- COMMUNICATION ID function is able to save the COMMUNICATION ID. The
COMMUNICATION ID has to be set if using the COMMUNICATION HEADER function.
- CRC(Cyclic Redundancy Checking) OPTION function is to set up whether CRC is used or not
during communication with host.
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...