スクリューカウンター                ─取扱説明書─ 
No. VSC-01 

 

 

 
 
 
 
 
 
 
 
 
 
 

○ご使用の前に、この取扱説明書をお読みください。 
○お読みになった後はいつでも参照できるように大切に保管してください。 

目    次 

●安全にお使いいただくために ·························· 2 
●製品の特長 ·········································· 4 
●本体仕様 ············································ 5 
●各部名称 ············································ 6 
●機能の説明 ·········································· 8 
●設定 ··············································· 13 
●保守/点検 ·········································· 15 
●保管 ··············································· 15 
●異常時の処置 ······································· 16 
●トラブルシューティング ····························· 16 
●保証書 ············································· 20 

 

 

Summary of Contents for VSC-01

Page 1: ...スクリューカウンター 取扱説明書 No VSC 01 ご使用の前に この取扱説明書をお読みください お読みになった後はいつでも参照できるように大切に保管してください 目 次 安全にお使いいただくために 2 製品の特長 4 本体仕様 5 各部名称 6 機能の説明 8 設定 13 保守 点検 15 保管 15 異常時の処置 16 トラブルシューティング 16 保証書 20 ...

Page 2: ...制 する内容です 注意 禁止 急激に温度変化する環境や結露する場所では使用しないでください 故障のお それがあります 水濡禁止 水 油 溶剤がかかるような場所や湿気の多い場所で使用しないでください 感電や故障のおそれがあります 禁止 仕様に示された電源の規格以外で使用しないでください 火災 感電のおそれがあります 禁止 本書を理解できるまでは 製品の設置 使用 保守をしないでください 必ず守る 本書は簡単に参照できるように 製品のそばに保管してください 警告 1 弊社の対応機種の VE シリーズ以外の電動ドライバーと接続しないでください 事故の原因と なります 2 作業場は いつもきれいに保ってください 散らかった場所や作業台は 事故の原因となります 3 作業場の周囲状況も考慮してください 高温 多湿 直射日光の当る場所 ゴミやホコリの多い場所でのご使用は避けてください 作業場は十分に明る...

Page 3: ...故やけがの原因になります 8 分解したり 強い衝撃 振動を与えたりしないでください 本製品は精密機器ですので分解しない でください 過剰な衝撃や振動により 機器が故障した場合 十分な性能を発揮しないだけでなく 事故やけがの原因となります 9 外部機器と接続する場合は すべての機器の電源を切った上で接続してください 感電又は機器損 傷の恐れがあります 10 取扱説明書の内容以外の状況が起きた場合は 直ちに使用を止めてお問い合わせください 注意 1 使用しない場合は きちんと保管してください 乾燥した場所で 子供の手の届かない高い場所又 は 鍵のかかるところに保管してください また 輸送する場合は 本製品の入っていた梱包箱を ご使用ください 2 きちんとした服装で行ってください だぶだぶな衣装や ネックレス等の装身具は 回転部に巻き 込まれる恐れがありますので着用しないで下さい 3 無理な姿勢...

Page 4: ...000 を除きます 特長 カウンター機能 カウント 締め付けネジ数をカウントし 積算または減算して残りの本数を表示します ポカヨケ 設定された本数まで締め付けると 完了をアラーム音と光で知らせます 本数管理 設定された本数まで締め付けないと 次の操作に移れません 増し締め 締め付け後に増し締めできます 増し締め可能時間を設定できます 締め不良 締め不足やネジ間違いをアラーム音と光で知らせることができます スロースタート機能 締め始めは低速で回転し その後通常の回転に戻るよう設定できます 外部信号入力 出力 外部機器 PLC やセンサーと組み合わせて ネジ締め作業の工程を制御することができます ...

Page 5: ... 5 チャンネル カウント本数 1 99 カウント方式 カウントアップ カウントダウン 切替可能 オートリセット時間 0 0 9 9 秒 スロースタート設定時間 0 0 9 9 秒 スロースタート時回転数 30 35 40 45 50 60 65 70 80 85 10 段階 ネジ締め時間 上限時間 0 01 9 90 秒 ネジ締め時間 下限時間 0 01 9 90 秒 寸法 150 65 32 mm 重量 180g 使用温度 湿度 0 40 10 80 RH 付属品 取扱説明書 本書 専用ターミナルブロック 対応機種 VE 1500EPA VE 2000EPA VE 3000 VE 4000 VE 4000P VE 4500 VE 4500P ...

Page 6: ...6 各部名称 寸法図 各部名称 1 ネジ長 12mm以上のネジで固定すると基盤を破損することがあります 接続方法 下図に従い 各機器を正しく接続してください VE 1500EPA VE 2000EPA シリーズの場合 3P6P 変換コードは VE 1500EPA VE 2000EPA 本体に付属しています ...

Page 7: ...7 各部名称 VE 3000 シリーズの場合 VE 4000 VE 4500 シリーズの場合 接続前にご使用の電動ドライバーとコントローラーが正しい組み合わせであることを確認してく ださい 間違った組み合わせで接続 使用されますと 電動ドライバーから発熱および発煙し 機器の故 障または作業者が負傷する危険性があります ...

Page 8: ... 秒長押しで設定モードに切り替わります 複数回押すと機能メニューが順に変わります エンター ディップスイッチ SW3がオンの時 確認キー エンター として 機能します アップ チャンネル設定 キーを押すとチャンネル番号が1ずつ上がります ダウン チャンネル設定 キーを押すとチャンネル番号が1ずつ下がります アップ ダウン 同時押し アラーム音の設定をすることができます 下の表を参考 初期化 システムが不安定なときなどに 工場出荷状態に戻します 初期化するとアラーム音が4回鳴ります アップ モード切替 エンター 同時押し 機能ボタンをロックします 機能ボタンのロックを解除します アラームの表示と設定 表示 OK 時のアラーム エラー時のアラーム OK ALL 時のアラーム ON ON ON OFF ON OFF OFF ON ON ON OFF ON ...

Page 9: ...ル終了と信号出力されます ピッピッピッ 3 回 下限時間に満たない時に警告します 設定時間より早くトルクアップ ねじかじりなどの可能性があります ピッピッピッピッ 4 回以上 上限時間を超過する時に警告します 設定時間経過後もトルクアップしていない オーバートルクなどの可能性があります ピーピッピッピッピッ 5 回以上 ワーク検出センサー使用時 作業途中にワークが取り外され た時警告します ワークを作業位置に戻すか 再度ゲートを通過させることでアラーム解除できます 外部入出力端子の説明 ...

Page 10: ...します 設定数のねじ締めが終了すると OK ALL 作業終了 信号が出力されます ワークを作 業位置から取り外し 新しいワークを配置 ねじ締め作業を開始します ゲートスイッチとの連動 スイッチ数 2 パルス信号 スクリューカウンターの電源をオフ 電源 リセットキーの長押し 5 秒 にしてから作業 します 付属のターミナルブロックに外部スイッチを正しく接続し 底面の出入力端子 に差し込みます ディップスイッチ SW2 がオン SW4 もオンになっていることを確認します ワークを作業位置に配置した後 スクリューカウンターの電源をオンにして作業を開始 します この際 電源をオンにしてからワークをゲート通過させるとエラーになります 作業途中にワークがゲートを通過すると スクリューカウンターがアラーム音と信号で 警告します 再度ゲートを通過させるとアラーム音が止まり エラー前の状態に復帰し ます 設...

Page 11: ... CN5 COM 共通 GND 入出力の COM など外部機器用 電源のマイナス などの共通 端子です CN6 GATE 入力 外部センサー信号の選択 本体背面のディップス イッチで ワーク検出スイッチとゲートスイッチ を切り替えます 無電圧接点入力 A ワークセンサ検出 ワーク検出をレベル入力信号 として受け付けます B ゲートセンサ検出 工程の開始と終了をパルス信 号のカウントで入力信号とし て受け付けます CN7 CLR 入力 外部リセット入力信号 1 工程のカウント信号などが リセットされ スタート待ち 受け状態に戻ります ディップスイッチ説明 SW No モード OFF 時 ON 時 SW1 カウントモード カウントダウン カウントアップ SW2 センサースイッチ 無効 有効 SW3 カウントリセット オートゼロ マニュアルリセット SW4 外部センサー使用数 センサー1個 セン...

Page 12: ...FF OFF センサー1個で作業開始を管理 自動でカウントリセットする場合 ON OFF ON センサー2個で作業開始を管理 自動でカウントリセットする場合 OFF ON OFF センサー使用せず モード切替 エンターキーを押して手動でリセットす る場合 ON ON OFF センサー1個で作業開始を管理 モード切替 エンターキーを押して手動 でリセットする場合 ON ON ON センサー2個で作業開始を管理 モード切替 エンターキーを押して手動 でリセットする場合 リセット信号の入力があったとき エラー ...

Page 13: ...ャンネル ネジの種類が変わる場合に設定 カウント数 同じネジごとに本数を設定 オートリセット時間 締め付け後 カウントが自動的にリセ ットされるまでの時間を設定 スロースタート設定時間 スロースタート時の回転数は以下の通りです 表示 30 40 45 50 60 65 70 80 85 スロースタート設定時間が 0 の時 と表示されます ネジ締め時間 上限時間 ネジ締め時間 下限時間 増し締め時間 オートリセット遅延 の場合にエラーを出します 1 100 秒台の設定は キーを押して表示を切り替えることができます 再度 キーを押すと元に戻ります スロースタート設定時は増し締め設定が無効になります スロースタート回転中のトルクアップは使用できません ...

Page 14: ...けできていないのに OK 判定される場合には 手動で標 準時間の調整を行ってください チャンネル連動設定方法 1つの工程内で ネジ径が同じでネジ長さが違うネジや ネジ径が違っても同じトルクで締め付けるネジはチャンネ ル連動機能を使って同時に作業することができます チャンネル連動設定方法 電源 リセットキー を押し カウントをリセットします ディスプレイに ねじ数設定モード で設定したねじ数が表示されている状態で 本体底面のディップ スイッチ SW6 をオンにします 設定すると と表示されます とはチャンネル連動設定時のチャンネル1 はチャンネル2 はチャンネル3を表しています 使用しないチャンネルは を0にしてください すべてチャンネルで初期設定が 5に設定されてい るので を を0にしないと設定しないと使用しないチャンネルも連動してしまいます チャンネル連動設定でチャンネルの順番を入れ替...

Page 15: ...があります 本機はお客様でメンテナンスするところはありません 表面を拭く場合 強化プラスチック製カバーを使用しておりますので以下のような化学薬品は 使用しないでください アセトン ベンジン シンナー ケトン エーテルその他同様の薬品 保管 注意 禁止 次のような場所に保管しないでください 故障のおそれがあります 本体に著しい振動や衝撃が加わる場所 仕様に示された範囲を超える高温多湿な場所 結露する場所 急激な温度変化のある場所 可燃性の溶剤や粉塵等 引火や爆発のおそれのある場所 ホコリ 粉塵 煙が多い場所 水 油 薬品等がかかる場所 強電界 強磁界が発生する場所 必ず守る 子供の手の届かないところに保管してください ...

Page 16: ...には電源スイッチを切り コントローラーを電源から抜いてください 分解禁止 分解 改造は絶対におこなわないでください 異常のままで使用した場合 製品の故障や事故の原因となります すみやかに修理を依頼してください 修理はお買 い上げの販売店にご相談ください トラブルシューティング 状況 原因 対策 電源が入らない コントローラーが未接続 接続不良 電源 が入っていない コントローラーを確実に接続してから 電 源を入れなおしてください スイッチ 回路基板の故障 ご購入の販売店へご相談ください カウントができない カウント設定が0になっている カウント設定を1以上にしてください 内部部品の故障 ご購入の販売店へご相談ください 設定をやり直したい 初期化ボタンを押してください ...

Page 17: ...17 MEMO ...

Page 18: ...18 MEMO ...

Page 19: ...19 MEMO ...

Page 20: ...じた損傷や故障 3 火災 地震 水害 落雷その他天災地変 ガス害 塩害 公害や異常電圧などによって生じた損傷 や故障 4 お買い上げ後の移動や輸送によって生じた損傷や故障 5 本書の紛失 所定事項の未記入または字句を書き換えられた場合 本書は再発行いたしませんので紛失しないよう大切に保管してください この保証書は 本製品の故障に対する無償修理または交換を保証するものであって 本製品の使用ま たは使用不能によって生じた損害に対して当社が責任を負うものではありません この保証書は 明示した期間 条件のもとにおいて無償修理をお約束するものです したがってこの 保証書によってお客様の法律上の権利を制限するものではございません 型式 VSC シリーズ 保証期間 お買い上げ日より 1 年間 お客様 お名前 ご住所 電話番号 販売店 店名 住所 電話番号 171225XX 002 Ver 1 Print...

Page 21: ...rting to use the product After reading keep the instruction manual around so the operators can refer the content whenever necessary Table of Contents For Safe Use P 2 Product Features P 6 Production Specifications P 7 Installation P 11 Operation P 12 Maintenance and Inspection P 14 Storage P 14 Procedures in Abnormal Conditions P 15 Warranty Certificate P 16 ...

Page 22: ...f fire or electric shock PROHIBITED Do not use the product in an environment with an abrupt temperature change or dew condensation Risk of product breakdown PROHIBITED Do not install use or conduct maintenance of the product unless the contents of this manual are fully understood REMEMBER Be sure to store this manual near the product so the operators can refer to the contents easily Warning 1 Do n...

Page 23: ...or vibration could prevent the required performance from being attained and could lead to accidents or injuries 9 Always turn the power of all devices off before connecting this product with an external device There is a risk of electric shock or device damage 10 If a situation other than those described in the instruction manual occurs stop using immediately and contact Vessel Caution 1 Store the...

Page 24: ...g or an incorrect screw can be notified with an alarm sound and light Screw tightening upper limit lower limit time setting function Differences in the screw length error in length can be judged Slow start function This function can be set to rotate at a low speed at the start of tightening and then return to a normal speed This function is effective for precision small screws resin tapping etc Ex...

Page 25: ...art setting time 0 0 to 9 9 seconds Speed at slow start 30 35 40 45 50 60 65 70 80 85 10 step Screw tightening time upper limit time 0 01 to 9 90 seconds Screw tightening time lower limit time 0 01 to 9 90 seconds Connector Dedicated connector open collector 7 contacts Dimensions 150 65 32 mm Weight 180g Working temperature humidity 0 to 40 C 10 to 80 RH Accessories Instruction manual this manual ...

Page 26: ... drawing Name of each part 1 The substrate can be damaged if fixed with a screw that is 12mm or longer Connection method For VE 1500EPA and VE 2000EPA Series The 3P6P converter cord is provided with the VE 1500EPA and VE 2000EPA unit ...

Page 27: ...onnect each device correctly Before connecting confirm that the combination of electric screwdriver and controller used is correct Connection with and or use of an incorrect combination of device could cause the electric screwdriver to generate heat and smoke the device to fail or the operator to get injured ...

Page 28: ...to reset the product to the factory defaults The alarm sounds four times when the settings are initialized Up Mode select Enter Press simultaneously Locks the function button Unlocks the function button Types of alarm sounds 1 Short beep once The torque up time is correct 2 Long beep The cycle end OK ALL is notified with a beep sound and a signal 3 Beep beep beep 3 times The alarm sounds when the ...

Page 29: ...w Unit piece Signal output time OK ALL sound time Signal Output Time Set the time that it takes for the count to be automatically reset after tightening at OK ALL Unit Second Slow start setting time Slow Start Time The speed at the start of screw tightening can be reduced Unit Second Revolution setting for slow start Slow Start Revolution The revolution setting is as shown below Display 30 40 45 5...

Page 30: ...crew Tightening Time can be measured 2 Prepare the workpiece and screw with which the screw tightening time should be set and carry out the actual screw tightening process When a screw is tightened the measured time appears on the display This is the actual screw tightening time 3 Then turn the DIP switch 5 OFF The actual screw tightening time is saved as the screw tightening upper limit time 4 As...

Page 31: ...el settings 1 Turn DIP switch SW 6 ON 2 appear on the display refers to channel 1 in channels interlocking For example when the channels 1 2 and 3 should be activated set zero on of so that the channel 4 and subsequent ones are not interlocked External input output By using the external input output terminal the screw tightening process can be controlled in combination with the programmable logic ...

Page 32: ...Workpiece sensor detection The workpiece detection is received as a level input signal B Gate sensor detection The start and end of the process is received as a pulse input signal CN7 CLR Input External reset input signal The count signal etc for one process is reset and the device returns to the start standby state Working with workpiece detection switch Number of switch 1 level signal 1 Turn OFF...

Page 33: ...k end signal is output The electric screwdriver does not operate until the completed workpiece passes through the end gate 6 Pass a new workpiece through the gate and start the screw tightening process DIP switch combinations Work control using sensors and displays SW2 SW3 SW4 Display ON OFF OFF Controls the start of process with one sensor when automatically resetting the count ON OFF ON Controls...

Page 34: ...ilar chemicals Storage CAUTION PROHIBITED Do not store the product in the following locations Risk of product breakdown Where a marked vibration or shock is applied to the main body A place that is hot and highly humid beyond the range of the specifications Where dew condensation occurs Where an abrupt temperature change occurs Where the risk of ignition or explosion exists such as near flammable ...

Page 35: ...The count setting is set to 0 zero Set the count setting to 1 or more Internal parts are faulty Consult with your dealer The error cannot be released The screw tightening lower limit time is higher than the screw tightening upper limit time Reset the screw tightening lower limit time Settings are incapable The keys are locked Press the keys simultaneously The settings are not saved The DIP switche...

Page 36: ...age pollution abnormal voltage etc 4 Damage and or breakage occurred due to transfer or transportation after purchase 5 Loss of this warranty certificate not filling out the specified section or when the words of this warranty certificate are tampered with This warranty certificate cannot be re issued Keep it safely and do not lose it This warranty certificate only warrants a free repair or replac...