12 Fault elimination
Maschinenfabrik Reinhausen GmbH 2015
224
4349315/00 EN
VACUTAP® VR®
Error pattern
Action
Tripping of pressure relief device (for example
MPreC®)
Remove diverter switch insert following maintenance
manual for the relevant on-load tap-changer. De-
pending on the cause of tripping, take measure-
ments/carry out checks on the transformer.
Tripping of pressure-operated relay (for example DW
2000)
Remove diverter switch insert following maintenance
manual for the relevant on-load tap-changer. De-
pending on the cause of tripping, take measure-
ments/carry out checks on the transformer.
Activation of tap-change supervisory control
Remove diverter switch insert following maintenance
manual for the relevant on-load tap-changer. De-
pending on the cause of tripping, take measure-
ments/carry out checks on the transformer.
Activation of rupture disk in on-load tap-changer
head cover
Remove diverter switch insert following maintenance
manual for the relevant on-load tap-changer. De-
pending on the cause of tripping, take measure-
ments/carry out checks on the transformer.
Tripping of motor protective switch in motor-drive
unit
Request "Information sheet on motor protective
switch tripping" from MR, complete and return to
MR.
Tripping of signaling contact that indicates that the
oil has fallen below the minimum oil level in the on-
load tap-changer oil conservator
Check pipework system (pipes etc.) and on-load tap-
changer head for leaks. Check oil level and oil quali-
ty of diverter switch oil in accordance with operating
instructions for on-load tap-changer. If the oil falls
below the limit values, also contact MR.
On-load tap-changer not changing tap position (slug-
gishness, Raise keys/Lower keys not working, divert-
er switch action not audible)
Contact MR.
No change in voltage on transformer despite change
in position on motor-drive unit
Contact MR.
Tap position indicator on motor-drive unit and on-
load tap-changer different
Contact MR.
Noises on drive shaft or motor-drive unit when
changing tap position
Ensure proper mounting of the drive shaft in accord-
ance with its operating instructions. Check that hose
clips and protective covers are seated correctly.
Contact MR in the event of noise from the motor-
drive unit.
Red message on monitoring unit
If possible read out database and send to MR along
with error code.
Warning or tripping of Buchholz relay on transformer Notify manufacturer of transformer.
Deviation from desired value when measuring wind-
ing resistance of transformer
Contact manufacturer of transformer and, if necessa-
ry, MR and provide measured values.
Deviation from desired value during dissolved gas
analysis (transformer oil)
Contact manufacturer of transformer and, if necessa-
ry, MR and provide measured values.
Summary of Contents for VACUTAP VR
Page 1: ...On Load Tap Changer VACUTAP VR Installation and Commissioning Instructions 4349315 00 EN ...
Page 246: ...14 Appendix Maschinenfabrik Reinhausen GmbH 2015 246 4349315 00 EN VACUTAP VR ...
Page 248: ...14 Appendix Maschinenfabrik Reinhausen GmbH 2015 248 4349315 00 EN VACUTAP VR ...
Page 266: ......
Page 267: ......