![Mitsubishi FR-A740-00023-EC Instruction Manual Download Page 80](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251080.webp)
70
Param
e
te
r List
Parameter List
Sl
ip
com
p
ensat
ion
245
Rated slip
0 to 50%, 9999
0.01%
9999
143
246
Slip compensation time constant
0.01 to 10s
0.01s
0.5s
143
247
Constant-power range slip
compensation selection
0, 9999
1
9999
143
⎯
250
Stop selection
0 to 100s,1000 to 1100s
8888, 9999
0.1s
9999
204
⎯
251
Output phase failure protection
selection
0, 1
1
1
264
F
requenc
y comp
ensat
ion
fu
n
cti
o
n
252
Override bias
0 to 200%
0.1%
50%
278
253
Override gain
0 to 200%
0.1%
150%
278
Lif
e
c
heck
255
Life alarm status display
(0 to 15)
1
0
374
256
Inrush current limit circuit life display
(0 to 100%)
1%
100%
374
257
Control circuit capacitor life display
(0 to 100%)
1%
100%
374
258
Main circuit capacitor life display
(0 to 100%)
1%
100%
374
259
Main circuit capacitor life measuring
0, 1
1
0
374
⎯
260
PWM frequency automatic switchover
0, 1
1
1
272
P
o
wer f
a
ilure
st
op
261
Power failure stop selection
0, 1, 2, 11, 12
1
0
258
262
Subtracted frequency at deceleration
start
0 to 20Hz
0.01Hz
3Hz
258
263
Subtraction starting frequency
0 to 120Hz, 9999
0.01Hz
50
Hz
258
264
Power-failure deceleration time 1
0 to 3600/360s
0.1/0.01s
5s
258
265
Power-failure deceleration time 2
0 to 3600s/360s,
9999
0.1/0.01s
9999
258
266
Power failure deceleration time
switchover frequency
0 to 400Hz
0.01Hz
50
Hz
258
⎯
267
Terminal 4 input selection
0, 1, 2
1
0
275
⎯
268
Monitor decimal digits selection
0,1, 9999
1
9999
244
⎯
269
Parameter for manufacturer setting. Do not set.
⎯
270
Stop-on contact/load torque high-
speed frequency control selection
0, 1, 2, 3
1
0
205,
361
Load t
o
rq
ue
high s
peed f
requenc
y
cont
rol
271
High-speed setting maximum current
0 to 220%
0.1%
50%
361
272
Middle-speed setting minimum current
0 to 220%
0.1%
100%
361
273
Current averaging range
0 to 400Hz, 9999
0.01Hz
9999
361
274
Current averaging filter time constant
1 to 4000
1
16
361
S
top-on cont
act
cont
ro
l
275
Stop-on contact excitation current low-
speed multiplying factor
0 to 1000%, 9999
0.1%
9999
205
276
PWM carrier frequency at stop-on
contact
0 to 9, 9999/
0 to 4, 9999
*2
1
9999
205
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting
Summary of Contents for FR-A740-00023-EC
Page 58: ...48 MEMO...
Page 70: ...60 MEMO...
Page 400: ...390 MEMO...
Page 450: ...440 MEMO...
Page 473: ...463 MEMO...