393
List of alarm display
5
P
R
OTECTIVE
FUNC
TI
ONS
5.2 List of alarm display
* If an error occurs when using the FR-PU04, "Fault 14" is displayed on
the FR-PU04.
Operation Panel
Indication
Name
Refer
to
E
rro
r m
es
sa
ge
E - - -
Alarm history
388
HOLD Operation panel lock
394
Er1 to 4 Parameter write error
394
rE1 to 4 Copy operation error
395
Err.
Error
395
Wa
rn
in
gs
OL
Stall prevention (overcurrent)
396
oL
Stall prevention (overvoltage)
396
RB
Regenerative brake prealarm
397
TH
Electronic thermal relay
function prealarm
397
PS
PU stop
396
MT
Maintenance signal output
397
CP
Parameter copy
397
SL
Speed limit indication
(Output during speed limit)
397
M
inor
fault
FN
Fan fault
397
Ma
jo
r fa
u
lt
E.OC1 Overcurrent shut-off during
acceleration
398
E.OC2 Overcurrent shut-off during
constant speed
398
E.OC3 Overcurrent shut-off during
deceleration or stop
398
E.OV1 Regenerative overvoltage
shut-off during acceleration
399
E.OV2 Regenerative overvoltage
shut-off during constant speed
399
E.OV3 Regenerative overvoltage shut-
off during deceleration or stop
399
E.THT Inverter overload shut-off
(electronic thermal relay function)
399
E.THM Motor overload shut-off
(electronic thermal relay function)
399
E.FIN
Fin overheat
400
E.IPF
Instantaneous power failure
400
E.BE
Brake transistor alarm
detection
400
E.UVT Undervoltage
400
E.ILF* Input phase failure
400
E.OLT Stall prevention
401
to
to
M
aj
o
r f
aul
t
E.GF
Output side earth (ground)
fault overcurrent
401
E.LF
Output phase failure
401
E.OHT External thermal relay
operation
*2
401
E.PTC* PTC thermistor operation
401
E.OPT Option alarm
402
E.OP3 Communication option alarm
402
E. 1 to
E. 3
Option alarm
402
E.PE
Parameter storage device
alarm
402
E.PUE PU disconnection
403
E.RET Retry count excess
403
E.PE2* Parameter storage device
alarm
403
/
/
E. 6 /
E. 7 /
E.CPU
CPU error
403
E.CTE
Operation panel power
supply short circuit, RS-485
terminal power supply short
circuit
403
E.P24 24VDC power output short
circuit
405
E.CDO* Output current detection
value exceeded
405
E.IOH* Inrush current limit circuit
alarm
405
E.SER* Communication error
(inverter)
405
E.AIE* Analog input error
405
E.OS
Overspeed occurence
404
E.OSD Speed deviation excess
detection
404
E.ECT Signal loss detection
404
E.OD
Excessive position error
404
E.MB1
to
E.MB7
Brake sequence error
403
E.EP
Encoder phase error
404
E.USB* USB communication error
405
E.11
Opposite rotation
deceleration error
406
E.13
Internal circuit error
406
Operation Panel
Indication
Name
Refer
to
to
to
Summary of Contents for FR-A740-00023-EC
Page 58: ...48 MEMO...
Page 70: ...60 MEMO...
Page 400: ...390 MEMO...
Page 450: ...440 MEMO...