417
Inspection item
6
P
R
EC
AUTIONS FOR MAINTE
NAN
CE AN
D
INS
P
E
C
T
IO
N
•
Reinstallation (FR-A740-00083 to 03610)
1)After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of "AIR FLOW" faces up.
<Fan side face>
2)Reconnect the fan connectors.
3)Reinstall the fan cover.
AIR FLOW
00083, 00126
00170 to 00380
00470, 00620
00770 to 03610
00083, 00126
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
00170 to 00620
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
00770 to 03610
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
CAUTION
•
Installing the fan in the opposite air flow direction can cause the inverter life to be shorter.
•
Prevent the cable from being caught when installing a fan.
•
Switch the power off before replacing fans. Since the inverter circuits are charged with voltage even after power off,
replace fans only when the inverter cover is on the inverter to prevent an electric shock accident.