69
Param
e
te
r List
Parameter List
4
P
ARAM
ETE
R
S
⎯
168
Parameter for manufacturer setting. Do not set.
⎯
169
Cumulativ
e
monit
o
r
clear
170
Watt-hour meter clear
0, 10, 9999
1
9999
244
171
Operation hour meter clear
0, 9999
1
9999
244
User
group
172
User group registered display/batch
clear
9999, (0 to 16)
1
0
299
173
User group registration
0 to 999, 9999
1
9999
299
174
User group clear
0 to 999, 9999
1
9999
299
input
t
e
rminal
fu
nct
ion as
signme
n
t
178
STF terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 60, 62, 64 to
71, 74, 9999
1
60
222
179
STR terminal function selection
0 to 20, 22 to 28, 37, 42 to
44, 50, 61, 62, 64 to 71,
74, 9999
1
61
222
180
RL terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62, 64 to 71,
74, 9999
1
0
222
181
RM terminal function selection
1
1
222
182
RH terminal function selection
1
2
222
183
RT terminal function selection
1
3
222
184
AU terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62 to 71, 74,
9999
1
4
222
185
JOG terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62, 64 to 71,
74, 9999
1
5
222
186
CS terminal function selection
1
6
222
187
MRS terminal function selection
1
24
222
188
STOP terminal function selection
1
25
222
189
RES terminal function selection
1
62
222
O
u
tput
t
e
rminal f
unct
ion as
signmen
t
190
RUN terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90 to 99,
100 to 108, 110 to 116,
120, 125 to 128, 130 to
136, 139, 141 to 147,
164, 170, 184, 185, 190
to 199, 9999
1
0
230
191
SU terminal function selection
1
1
230
192
IPF terminal function selection
1
2
230
193
OL terminal function selection
1
3
230
194
FU terminal function selection
1
4
230
195
ABC1 terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90, 91, 94 to
99, 100 to 108, 110 to
116, 120, 125 to 128, 130
to 136, 139, 141 to 147,
164, 170, 184, 185, 190,
191, 194 to 199, 9999
1
99
230
196
ABC2 terminal function selection
1
9999
230
M
u
lti-s
p
eed
se
tt
in
g
232 to 239
Multi-speed setting(8 speed to 15
speed)
0 to 400Hz, 9999
0.01Hz
9999
160
⎯
240
Soft-PWM operation selection
0, 1
1
1
278
⎯
241
Analog input display unit switchover
0, 1
1
0
282
⎯
242
Terminal 1 added compensation
amount (terminal 2)
0 to 100%
0.1%
100%
278
⎯
243
Terminal 1 added compensation
amount (terminal 4)
0 to 100%
0.1%
75%
278
⎯
244
Cooling fan operation selection
0, 1
1
1
373
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting
Summary of Contents for FR-A740-00023-EC
Page 58: ...48 MEMO...
Page 70: ...60 MEMO...
Page 400: ...390 MEMO...
Page 450: ...440 MEMO...
Page 473: ...463 MEMO...