187
Selection and protection of a motor
4
P
ARAME
T
E
R
S
(4) Utilizing or changing offline auto tuning data for use
The data measured in the offline auto tuning can be read and utilized or changed.
<Operating procedure>
1)Set
Pr. 71
according to the motor used.
*1 For other settings of
Pr. 71
, refer to the
page 179
.
2)In the parameter setting mode, read the following parameters and set desired values.
Motor
Pr. 71
Setting
*
Mitsubishi standard motor
Mitsubishi high efficiency
motor
SF-JR, SF-TH
4
SF-JR 4P 1.5kW or less
24
SF-HR
44
Others
4
Mitsubishi constant-torque
motor
SF-JRCA 4P
SF-TH (constant torque)
14
SF-HRCA 4P
54
Others (SF-JRC, etc.)
14
Vector control dedicated
motor
SF-V5RU
SF-THY
34
Other manufacturer's
standard motor
−
4
Other manufacturer's
constant torque motor
−
14
Parameter
Number
Name
Setting Range
Setting
Increments
Initial
Value
82
Motor excitation current
0 to ***, 9999
1
9999
90
Motor constant (R1)
0 to ***, 9999
1
9999
91
Motor constant (R2)
0 to ***, 9999
1
9999
92
Motor constant (L1)
0 to ***, 9999
1
9999
93
Motor constant (L2)
0 to ***, 9999
1
9999
94
Motor constant (X)
0 to ***, 9999
1
9999
859
Torque current
0 to ***, 9999
1
9999
REMARKS
· The display units of the motor constants read using
Pr. 684 Tuning data unit switchover
can be changed. Note that parameter
values can not be changed.
· When "9999" is set in
Pr. 82, Pr. 90
to
Pr. 94,
Pr. 455, Pr. 458
to
Pr. 462,
Pr. 859,
Pr. 860,
Mitsubishi motor (SF-JR, SF-HR,SF-
JRCA, SF-HRCA, SF-V5RU) constants are used.
· As the motor constants measured in the offline auto tuning have been converted into internal data (****), refer to the following
setting example when making setting:
Setting example
To slightly increase
Pr. 90
value (5%)
When
Pr. 90
is displayed "2516",
set 2642, i.e. 2516
×
1.05 = 2641.8, in
Pr. 90
.
(The value displayed has been converted into a value for internal use. Hence, simple addition of a given
value to the displayed value has no significance.)
Pr. 684
Setting
Pr. 82,
Pr. 455
Pr. 90,
Pr. 458
Pr. 91,
Pr. 459
Pr. 92,
Pr. 460
Pr. 93,
Pr. 461
Pr. 94,
Pr. 462
Pr. 859,
Pr. 860
0
Internal data converted value
1
01800 or
less
0.01A
0.001
Ω
0.001
Ω
0.1mH
0.1mH
0.1%
0.01A
02160 or
more
0.1A
0.01m
Ω
0.01m
Ω
0.01mH
0.01mH
0.01%
0.1A