65
Param
e
te
r List
Parameter List
4
P
ARAM
ETE
R
S
4.2 Parameter List
4.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel (FR-DU07).
REMARKS
⋅
indicates simple mode parameters. (initially set to extended mode)
⋅
The shaded parameters in the table allow its setting to be changed during operation even if "0" (initial value) is set in
Pr. 77 Parameter write
selection
.
⋅
Refer to the appendix 4 (
page 444
) for instruction codes for communication and availability of parameter clear, all clear, and parameter
copy of each parameter.
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting
Ba
si
c f
unc
tions
0
Torque boost
0 to 30%
0.1%
6/4/3/2
/1
%
*1
138
1
Maximum frequency
0 to 120Hz
0.01Hz
120
/60
Hz
*2
151
2
Minimum frequency
0 to 120Hz
0.01Hz
0Hz
151
3
Base frequency
0 to 400Hz
0.01Hz
50Hz
153
4
Multi-speed setting (high speed)
0 to 400Hz
0.01Hz
50Hz
160
5
Multi-speed setting (middle speed)
0 to 400Hz
0.01Hz
30Hz
160
6
Multi-speed setting (low speed)
0 to 400Hz
0.01Hz
10Hz
160
7
Acceleration time
0 to 3600/360s
0.1/0.01s
5/15s
*3
167
8
Deceleration time
0 to 3600/360s
0.1/0.01s
5/15s
*3
167
9
Electronic thermal O/L relay
0 to 500/0 to 3600A
*2
0.01
/0.1
A
*2
Rated inverter
current
175
DC inje
ct
io
n
brak
e
10
DC injection brake operation frequency
0 to 120Hz, 9999
0.01Hz
3Hz
194
11
DC injection brake operation time
0 to 10s, 8888
0.1s
0.5s
194
12
DC injection brake operation voltage
0 to 30%
0.1%
4/2
/1
%
*4
194
⎯
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
169
⎯
14
Load pattern selection
0 to 5
1
0
155
Jog
ope
rat
ion
15
Jog frequency
0 to 400Hz
0.01Hz
5Hz
162
16
Jog acceleration/deceleration time
0 to 3600/360s
0.1/0.01s
0.5s
162
⎯
17
MRS input selection
0, 2, 4
1
0
225
⎯
18
High speed maximum frequency
120 to 400Hz
0.01Hz
120
/60
Hz
*2
151
⎯
19
Base frequency voltage
0 to 1000V, 8888, 9999
0.1V
8888
153
Ac
ce
le
ra
tion
/
de
ce
lera
tio
n
ti
m
e
s
20
Acceleration/deceleration reference
frequency
1 to 400Hz
0.01Hz
50Hz
167
21
Acceleration/deceleration time
increments
0, 1
1
0
167
S
tall
p
rev
en
tio
n
22
Stall prevention operation level
(torque limit level )
0 to 400%
0.1%
150%
144
23
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999
0.1%
9999
144
Mult
i-sp
eed
se
tt
in
g
24 to 27
Multi-speed setting(4 speed to 7 speed)
0 to 400Hz, 9999
0.01Hz
9999
160
⎯
28
Multi-speed input compensation selection
0, 1
1
0
164
⎯
29
Acceleration/deceleration pattern
selection
0 to 5
1
0
170
⎯
30
Regenerative function selection
0, 1, 2, 10, 11, 20, 21
1
0
198
F
requ
enc
y
jump
31
Frequency jump 1A
0 to 400Hz, 9999
0.01Hz
9999
152
32
Frequency jump 1B
0 to 400Hz, 9999
0.01Hz
9999
152
33
Frequency jump 2A
0 to 400Hz, 9999
0.01Hz
9999
152
34
Frequency jump 2B
0 to 400Hz, 9999
0.01Hz
9999
152
35
Frequency jump 3A
0 to 400Hz, 9999
0.01Hz
9999
152
36
Frequency jump 3B
0 to 400Hz, 9999
0.01Hz
9999
152
⎯
37
Speed display
0, 1 to 9998
1
0
242