![Mitsubishi FR-A740-00023-EC Instruction Manual Download Page 140](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251140.webp)
130
Position control by vector control
(3) Selection of clear signal (
Pr. 429
, CLR signal)
⋅
Use this function to zero the droop pulse for home position operation, etc.
⋅
When "0" is set in
Pr. 429
, the deviation counter is cleared at the edge of truning on of the clear signal (CLR). In
addition, the CLR signal turns on in synchronization with zero pulse signal of the encoder at home position
operation, etc., deviation counter is cleared.
⋅
For the terminal used for CLR signal, set "69" in any of
Pr. 178 to Pr. 189 (input terminal function selection)
to assign
the function.
(4) Pulse monitor selection (
Pr. 430
)
The status of various pulses during running is displayed.
Set "6" in
Pr. 52 DU/PU main display data selection
to display output frequency monitor.
Pr. 430
Setting
Description
Display Range
(FR-DU07)
Display Range
(FR-PU04/FR-PU07)
0
The cumulative command pulse value is displayed.
Lower 4 digits
Lower 5 digits
1
Upper 4 digits
Upper 5 digits
2
The cumulative feedback pulse value is displayed.
Lower 4 digits
Lower 5 digits
3
Upper 4 digits
Upper 5 digits
4
The droop pulses are monitored.
Lower 4 digits
Lower 5 digits
5
Upper 4 digits
Upper 5 digits
9999
Frequency monitor is displayed. (initial value)
REMARKS
⋅
Count the number of pulses when the servo is on.
⋅
The cumulative pulse value is cleared when the base is shut off or the clear signal (CLR) is turned on.
CAUTION
⋅
Changing the terminal assignment using
Pr. 178 to Pr. 189 (input terminal function selection)
may affect the other functions. Make
setting after confirming the function of each terminal.
♦
Parameters referred to
♦
Pr. 52 DU/PU main display data selection
Refer to page 244
Pr. 178 to Pr. 189 (input terminal function selection)
Refer to page 222
Deviation counter
image
CLR
ON
When
Pr. 429
= "0"
When
Pr. 429
= "1 (initial value)"
Deviation counter
image
CLR
ON
Counter clear while ON
Counter clear at the edge of
turning on of the signal