![Mitsubishi FR-A740-00023-EC Instruction Manual Download Page 339](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251339.webp)
329
Communication operation and setting
4
P
ARAME
T
E
R
S
Example) When reading the
C3 (Pr. 902) and C6 (Pr. 904)
settings from the inverter of station 0
To read/write
C3 (Pr. 902)
and
C6 (Pr. 904)
after inverter reset or parameter clear, execute from 1) again.
8
All parameter
clear
Write
HFC
All parameters return to the initial values.
Any of four different all clear operations are performed according to
the data.
When all parameter clear is executed for H9696 or H9966,
communication-related parameter settings also return to the initial
values. When resuming operation, set the parameters again.
*1
Refer to
page 320, 321
.
*2
Refer to the list of calibration parameters on the next page for calibration
parameters.
*3
Pr. 75
is not cleared
4 digits
(A,C/D)
9
Parameters
Read
H00 to
H63
Refer to the instruction code
(page 444)
and write and/or read the
values as required.
When setting
Pr. 100
and later, link parameter extended setting must
be set.
4 digits
(B.E/D)
10
Write
H80 to
HE3
4 digits
(A,C/D)
11
Link parameter
extended setting
Read
H7F
Parameter description is changed according to the H00 to H09
setting.
For details of the setting, refer to the instruction code
(page 444)
.
2digits
(B.E'/D)
Write
HFF
2digits
(A',C/D)
12
Second
parameter
changing
(instruction code
HFF=1, 9)
Read
H6C
When setting the calibration parameters
*1
H00:Frequency
*2
H01: Parameter-set analog value
H02: Analog value input from terminal
*
1
Refer to the list of calibration parameters on the next page for calibration
parameters.
*
2
The gain frequency can also be written using
Pr. 125
(instruction code
H99) or
Pr. 126
(instruction code H9A).
2digits
(B.E'/D)
Write
HEC
2digits
(A',C/D)
REMARKS
⋅
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
⋅
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Computer Send Data
Inverter Send Data
Description
1)
ENQ 00 FF 0 01 82
ACK 00
Set "H01" in the extended link parameter.
2)
ENQ 00 EC 0 01 7E
ACK 00
Set "H01" in second parameter changing.
3)
ENQ 00 5E 0 0F
STX 00 0000 ETX 25
C3 (Pr. 902)
is read. 0% is read.
4)
ENQ 00 60 0 FB
STX 00 0000 ETX 25
C6 (Pr. 904)
is read. 0% is read.
No.
Item
Read/
Write
Instruction
Code
Data Description
Number of
Data Digits
(format)
Refer to
page 323
for data formats (A, A', B, B', C, D)
Pr.
Communi-
cation Pr.
*1
Calibration
Pr.
*2
Other Pr.
*3
HEC
HF3
HFF
Data
H9696
×
H9966
H5A5A
×
×
H55AA
×