292
Frequency/torque setting by analog
input (terminal 1, 2, 4)
c) Method to adjust torque only without adjustment of gain voltage (current)
(when changing gain torque from 150% to 130%)
REMARKS
· For operation from the parameter unit (FR-PU04/FR-PU07), refer to the instruction manual of the FR-PU04/FR-PU07.
· Set bias torque setting using
calibration parameter C16 (Pr. 919) or C38 (Pr. 932)
.
(Refer to page 289 )
CAUTION
Take care when setting any value other than "0" as the bias torque at 0V (0mA). Torque is applied to the motor by
merely tuning on the start signal without torque command.
♦
Parameters referred to
♦
Pr. 20 Acceleration/deceleration reference frequency
Refer to page 167
Pr. 73 Analog input selection, Pr. 267 Terminal 4 input selection
Refer to page 275
Pr. 79 Operation mode selection
Refer to page 301
Pr. 858 Terminal 4 function assignment, Pr. 868 Terminal 1 function assignment
Refer to page 274
Flicker...Parameter setting complete!!
Display
Operation
1.
Pr.920
) or
(
Pr.933
) appears.
3.
Turn
o change the set value to
" " (130.0%)
4.
Press to set.
5.
Mode/monitor check
Press twice to choose the
monitor/frequency monitor.
6.
Apply a voltage across the inverter
terminals 1-5 (across 4-5) and turn on the
start command (STF, STR).
Operation starts with 130% torque.
2.
Press to show the currently set value.
(150%)
or
Terminal 1 input
Terminal 4 input
Terminal 1 input Terminal 4 input