![Mitsubishi FR-A740-00023-EC Instruction Manual Download Page 149](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251149.webp)
139
Adjust the output torque of the motor (current)
4
P
ARAME
T
E
R
S
(2) Set multiple torque boost (RT signal, X9 signal,
Pr. 46, Pr. 112
)
⋅
Use the second (third) torque boost when changing the torque boost according to application or when using
multiple motors by switching between them by one inverter.
⋅
Pr. 46 Second torque boost
is made valid when the RT signal turns on.
⋅
Pr. 112
Third torque boost
is valid when the X9 signal is on. For the terminal used for X9 signal input, set "9" in any of
Pr. 178
to
Pr. 189
(input terminal function selection) to assign the X9 signal function.
REMARKS
⋅
The RT(X9) signal acts as the second
(third)
function selection signal and makes the other second
(third)
functions valid.
(Refer to page 226)
⋅
The RT signal is assigned to the RT terminal in the default setting. By setting "3" in any of
Pr. 178 to Pr. 189 (input terminal function
selection)
, you can assign the RT signal to the other terminal.
CAUTION
⋅
Increase the setting when the distance between the inverter and motor is long or when motor torque is insufficient in the low-
speed range. If the setting is too large, an overcurrent trip may occur.
⋅
The
Pr. 0, Pr. 46, Pr. 112
settings are valid only when V/F control is selected.
⋅
When using the inverter dedicated motor (constant torque motor) with the 00170 or 00250, set the torque boost value to 2%. If
the initial set
Pr. 71
value is changed to the setting for use with a constant-torque motor, the
Pr. 0
setting changes to the
corresponding value in above.
⋅
Changing the terminal assignment using
Pr. 178 to Pr. 189 (input terminal function selection)
may affect the other functions. Please
make setting after confirming the function of each terminal.
♦
Parameters referred to
♦
Pr. 3 Base frequency, Pr. 19 Base frequency voltage
Refer to page 153
Pr. 71 Applied motor
Refer to page 179
Pr. 178 to Pr. 189 (Input terminal function selection)