![Mitsubishi FR-A740-00023-EC Instruction Manual Download Page 44](http://html1.mh-extra.com/html/mitsubishi/fr-a740-00023-ec/fr-a740-00023-ec_instruction-manual_1809251044.webp)
34
Connection of motor with encoder (vector control)
(5) Wiring
• Speed control
• Torque control
Standard motor with encoder (SF-JR), 5V differential line driver
Vector control dedicated motor,
12V complimentary
Standard motor with encoder (SF-JR), 5V differential line driver
Vector control dedicated motor,
12V complimentary
*1
The pin number differs according to the encoder used.
Speed control and torque control are properly performed even without connecting Z phase.
*2
Connect the encoder so that there is no looseness between the motor and motor shaft. Speed ratio should be 1:1.
*3
Earth (Ground) the shielded cable of the encoder cable to the enclosure with a P clip, etc.
(Refer to page 36.)
*4
For the complementary, set the terminating resistor selection switch to off position.
(Refer to page 32.)
*5
A separate power supply of 5V/12V/15V/24V is necessary according to the encoder power specification.
*6
For terminal compatibility of the FR-JCBL and FR-A7AP, refer to
page 33
.
Three-phase
AC power supply
MCCB
R/L1
S/L2
T/L3
SF-JR motor
with encoder
U
V
W
U
V
W
E
C
*3
*1
*2
*4
*6
R
PA1
FR-A7AP
PA2
PB1
PB2
PZ1
PZ2
PG
PG
SD
SD
Differential
Terminating
resistor ON
OFF
Complimentary
A
N
B
P
H
K
IM
Forward rotation start
Reverse rotation start
Contact input common
STF
STR
SD
Encoder
Earth
(Ground)
Inverter
10
2
2
3
1
1
Frequency command
Frequency setting
potentiometer
1/2W1k
Ω
5
(+)
(-)
5VDC power supply
*5
(+)
(-)
Torque limit
command
( 10V)
U
V
W
U
V
W
E
IM
Inverter
Earth
(Ground)
*4
*3
PA1
FR-A7AP
PA2
PB1
PB2
PZ1
PZ2
*1
A
*2
B
C
D
F
G
S
R
(+)
(-)
Differential
Terminating
resistor
ON
OFF
Complimentary
Encoder
12VDC power supply
*5
PG
PG
SD
SD
*6
Three-phase
AC power supply
MCCB
R/L1
S/L2
T/L3
SF-JR motor
with encoder
U
V
W
U
V
W
E
C
*3
*1
*2
*4
*6
R
PA1
FR-A7AP
PA2
PB1
PB2
PZ1
PZ2
PG
PG
SD
SD
Differential
Terminating
resistor ON
OFF
Complimentary
A
N
B
P
H
K
IM
Forward rotation start
Reverse rotation start
Contact input common
STF
STR
SD
Encoder
Earth
(Ground)
Inverter
10
2
2
3
1
1
Speed limit command
Frequency setting
potentiometer
1/2W1k
Ω
5
(+)
(-)
5VDC
power supply
*5
(+)
(-)
Torque command
( 10V)
U
V
W
U
V
W
E
IM
Inverter
Earth
(Ground)
*4
*3
PA1
FR-A7AP
PA2
PB1
PB2
PZ1
PZ2
*1
A
*2
B
C
D
F
G
S
R
(+)
(-)
Differential
Terminating
resistor
ON
OFF
Complimentary
Encoder
12VDC power supply
*5
PG
PG
SD
SD
*6