13. Program Support Functions
13.17 High-speed High-accuracy Control; G05, G05.1
431
Parameter standard values
The standard values of the parameters related to SSS control are shown below.
(1) Machining
parameters
# Item
Standard
value
8019 R
COMP
0
8020 DCC
ANGLE
10
8021 COMP
CHANGE
1
8022 CORNER
COMP
0
8023 CURVE
COMP
-20
8029 Fairing
L
0
8033 Fairing
ON
0
8034 AccClamp
ON
0
8036 CordecJudge
0
8037 CorJudgeL
0
(Note)
Reference items for adjusting the parameter
The relation of each parameter, the accuracy and the speed is shown below.
The accuracy and speed required for machining can be adjusted with these settings.
When adjusting the parameters, adjust the values within the range in which the
machine does not vibrate.
Parameter Adjustment
target
Effect
#8022 CORNER COMP
Accuracy at
corner section
Large setting = Accuracy improves, speed
drops
#8023 CURVE COMP
Accuracy at curve
section
Large setting = Accuracy increases, speed
drops
#8092 ClampCoeff
Accuracy at curve
section
Large setting = Accuracy drops, speed
increases
(Note) Usually use the standard value and
adjust with "#8023".
(2) Basic specification parameters
# Item
Standard
value
1148
I_G611
Initial high accuracy
0
1205
G0bdcc
G0 before interpolation
0
1206 G1bf
Acceleration/deceleration before
interpolation Maximum speed
-
1207 G1btL
Acceleration/deceleration before
interpolation Time constant
-
1209 Cirdcc
Arc deceleration speed
-
1267
ext03/bit0
G code type
1
1572
Cirorp
Arc command overlap
0
1568
SfiltG1
G1 soft acceleration/deceleration filter
0
1569
SfiltG0
G0 soft acceleration/deceleration filter
0
1570 Sfilt2
Soft
acceleration/deceleration filter 2
0