6. Interpolation Functions
6.1 Positioning (Rapid Traverse)
39
In-position width setting
When the servo parameter "#2224 SV024" setting value is smaller than the setting value of the G0
in-position width "#2077 G0inps" and the G1 in-position width "#2078 G1inps", the in-position
check is carried out with the G0 in-position width and the G1 in-position width.
In-position check using the
"G0inps" value
Command to motor
Outline of motor movement
G0 in-position
SV024
A stop is judged here.
In-position check using the
"G1inps" value
Command to motor
Outline of motor movement
G1 in-position
SV024
A stop is judged here.
When the SV024 value is larger, the in-position check is completed when the error amount is
smaller than the SV024 setting value.
The in-position check method depends on the method set in the deceleration check parameter.
(Note 1)
When the in-position width (programmable in-position check width) is set in the machining program,
either the in-position width set with the parameter (SV024, G0inps, G1inps) or that set in the
program, whichever larger, is applied when performing an in-position check.
(Note 2)
When the SV024 setting value is larger than the G0 in-position width/G1 in-position width, the
in-position check is carried out with the SV024 value.
(Note 3)
When the error detect is ON, the in-position check is forcibly carried out.