7. Feed Functions
7.8 Rapid Traverse Constant Inclination Multi-step Acceleration/Deceleration
128
Detailed description (S-pattern filter control)
With S-pattern filter control, this enables the rapid traverse inclination multi-step acceleration/
deceleration fluctuation to further smoothen.
This can be set in the range of 0 to 200 (ms) with the basic specification parameter "#1569 SfiltG0"
(G00 soft acceleration/deceleration filter). With "#1570 Sfilt2" (Soft acceleration/deceleration filter
2), this also enables the acceleration/deceleration fluctuation to further smoothen.
Time
Speed
Parameter setting = S Sfilt2
S-pattern filter
No S-pattern filter
Detailed description (Rapid traverse rate for the high-accuracy control mode)
The high-accuracy control mode's rapid traverse rate ("#2109 Rapid (H-precision)") can be set
besides rapid traverse rate ("#2001 rapid") during high-accuracy control, high-speed high-accuracy
control I/II or high-accuracy spline control.
Operation when the value is set at the high-accuracy control mode's rapid traverse rate is as
follows.
(1) When "The high-accuracy control mode rapid traverse rate" > "rapid traverse rate"
This function is invalid and operates as "rapid traverse constant inclination
acceleration/deceleration".
Rapid
traverse
rate
Speed
Time
Acceleration
Time
#2004 G0tL
(2) When "The high-accuracy control mode rapid traverse rate" < "rapid traverse rate"
"The high-accuracy control mode rapid traverse rate" is applied according to acceleration
pattern calculated from acceleration rate to "rapid traverse", "rated speed", "G0 time constant
to rated speed" and "maximum acceleration".