Appendix 1. Program Error
579
Error No.
Details
Remedy
P551
G06.2 knot error
The knot (k) command value is smaller than
the value for the previous block.
• Reconsider the program.
• Specify the knot by monotone increment.
P552
Start point of 1st G06.2 err
The block end point immediately before the
G06.2 command and the G06.2 first block
command value do not match.
• Match the G06.2 first block coordinate
command value with the previous block end
point.
P554
Invld manual interrupt in G6.2
Manual interruption using a block was
performed while in G06.2 mode.
• Perform for blocks other than G06.2 mode
when manually interrupting.
P555
Invalid restart during G06.2
Restart was attempted from the block in
G06.2 mode.
• Restart from the block other than in G06.2
mode.
P600
No spec: Auto TLM
An automatic tool length measurement
command (G37) was execute though there
are no such command specifications.
• Check the specifications.
P601
No spec: Skip
A skip command (G31) was issued though
there are no such command specifications.
• Check the specifications.
P602
No spec: Multi skip
A multiple skip command (G31.1‚ G31.2 or
G31.3) was issued though there are no such
command specifications.
• Check the specifications.
P603
Skip speed 0
The skip speed is 0.
• Specify the skip speed.
P604
TLM illegal axis
No axis or more than one axis was specified in
the automatic tool length measurement block.
• Specify only one axis.
P605
T & TLM command in a block
The T code is in the same block as the
automatic tool length measurement block.
• Specify this T code before the block.
P606
T cmnd not found before TLM
The T code was not yet specified in automatic
tool length measurement.
• Specify this T code before the block.
P607
TLM illegal signal
Before the area specified by the D command
or decelerating area parameter d‚ the
measurement position arrival signal went ON.
The signal remains OFF to the end.
• Check the program.
P608
Skip during radius compen
A skip command was specified during radius
compensation processing.
• Specify a radius compensation cancel (G40)
command or remove the skip command.
P610 Illegal
parameter
• The parameter setting is not correct.
• G114.1 was commanded when the spindle
synchronization with PLC I/F command was
selected.
• G113 was commanded when the
spindle-spindle polygon machining option
was OFF and the spindle synchronization
with PLC I/F command was selected.
• Check whether "#1549 Iv0vR1" to "#1553
Iv0vR5" are set in descending order (in order
of large values).
• Check whether "#1554 Iv0rd2" to "#1557
Iv0rd5" are set in descending order.
• Check and correct "#1514 expLinax" and
"#1515 expRotax".
• Check the program.
• Check the parameter.