5. Position Commands
5.3 Decimal Point Input
30
Addresses used and validity/invalidity of decimal point commands are shown below.
Address
Decimal point
command
Application
Remarks
A
Valid
Coordinate position data
Invalid
Revolving
table
Invalid
Miscellaneous function code
Valid
Angle
data
Invalid
Data settings, axis numbers (G10)
Invalid
Subprogram call : program No. (label O)
B
Valid
Coordinate position data
Invalid Revolving
table
Invalid
Miscellaneous function code
C
Valid
Coordinate position data
Invalid Revolving
table
Invalid
Miscellaneous function code
Valid
Corner chamfering amount
,c
D
Invalid
Compensation numbers (tool position, tool radius)
Valid
Automatic tool length measurement: deceleration
distance d
Invalid
Data setting: byte type data
Invalid
Subprogram storing device number
,D
E
Valid
Inch thread: number of ridges,
precision thread: lead
Valid
Dwell time at hole bottom of fixed cycle (label L, O)
F
Valid
Feedrate, automatic tool length measurement speed
Valid
Thread
lead
Valid
Number of Z axis pitch in synchronous tap
G
Valid
Preparatory function code
H
Invalid
Tool length compensation number
Invalid
Sequence number in subprogram (label L, O)
Invalid
Subprogram return destination sequence No. (label L, O)
Invalid
Program parameter input: bit type data
Invalid
Basic spindle selection
I
Valid
Arc center coordinates
Invalid
Center of figure rotation (incremental)
Valid
Tool radius compensation vector components
Valid
Hole pitch in the special fixed cycle
Valid
Circle radius of cut circle (increase amount)
Valid
G0/G1 imposition width, drilling cycle G0 imposition width ,I
Valid
Stroke check before travel: lower limit coordinates