138
APPX
Appendix 1 Remote I/O Signals
Address inspection command
■
Device No.
■
Description
When Address inspection command (RY2) is turned off and on, the automatic inspection is executed.
For details on address inspection, refer to the following.
Page 61 Address Inspection Function
Module parameter reflection request flag
■
Device No.
■
Description
This flag is used when setting module parameters in the program.
After writing the parameter data to the remote buffer memory, turn on Module parameter reflection request flag (RYC) to write
the parameter data to the non-volatile memory.
Power off and on the system or perform the remote reset and the module starts operating with the saved settings.
AnyWireASLINK version compatibility inspection command
■
Device No.
■
Description
Turn on this signal to execute the AnyWireASLINK version compatibility inspection.
Slave module parameter access request command
■
Device No.
■
Description
Turn on this signal to perform the following operations from the NZ2AW1GNAL to a slave module.
• Read or write the parameter of the slave module.
• Execute the remote address change function.
Name
Device No.
Address inspection command
RY2
Name
Device No.
Module parameter reflection request flag
RYC
Name
Device No.
AnyWireASLINK version compatibility inspection command
RYD
Name
Device No.
Slave module parameter access request command
RY10
Summary of Contents for AnyWire ASLINK
Page 1: ...CC Link IE TSN AnyWireASLINK Bridge Module User s Manual NZ2AW1GNAL ...
Page 2: ......
Page 22: ...20 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 96: ...94 8 PROGRAMMING 8 2 Program Example Program ...
Page 100: ...98 8 PROGRAMMING 8 2 Program Example Program ...
Page 101: ...8 PROGRAMMING 8 2 Program Example 99 8 ...
Page 199: ......