Operation
CSP2008
5.3.10.1
Definitions
The block number of the previous
module must always be used for the
definition of data sources of a pro-
gram.
Confirm all settings with
Submit
before you activate another button or
menu item.
Submit
Program selection:
Data source:
Average
Block 1 - Calculation
Averaging type:
Recursive
Average value:
5
Block 2
Averaging
Block 1
Calculation
Block 2
The sensor inputs on the front side
of the controller have different output
numbers. This is important for the
definition of the data sources, e.g. in
the
Calculation
module.
Block 1
Calculation
Data source 1
Sensor 1
Data source 2
Sensor 2
Sensors, controller with EtherCAT
interface at the EtherCAT connec-
tion are led in the CSP2008 with the
designation
Sensor 3
.
Block 1
Calculation
Data source n
Sensor 3
opto
NCDT
ERR
P wer on
RUN
Ethe CAT Ethernet
aser ff
In range
Mid ange
Error
F=1 5. . 0 kHz;
=670 nm
L se str h un
Ni ht in d n tr hl b i ken
L ser l sse 2
nach D N N 0825-1 20 8-05
t= ,5 . 542 µs
P =1,2 mW;
P
1 mW;
P
Sensors at the RS422 extension
terminals are led in the controller with
the designations
Sensor 3
up to
sensor 6.
Maximum two RS422
extension terminals are possible.
Connected sensors can be synchro-
nized.
L/A
L/A
RUN
24V
24V
0V
0V
PE
PE
Laser
GND
Sensor 1
Sensor 2
L/A
L/A
RUN
24V
24V
0V
0V
PE
PE
Laser
GND
Sensor 1
Sensor 2
Data source 2
Sensor 6
Data source 1
Sensor 3
Summary of Contents for CSP2008
Page 1: ...CSP2008 Instruction Manual Channel 1 in mm 14 452...
Page 79: ......