Page 70
Programming the Controller with the Function Keys
CSP2008
C. Definition of the sensor connections
Press the button to change to
Data recording
. Con-
firm the selection with the button .
Settings
Digital CSP2008 inputs
EtherCAT-Devices
Data recording
Calculation
Data output
Activate the menu
Sensor 1
with the
button .Select
the menu
Sensor 1
with the button . Press again the
button , to reach the
Sensor selection
list. Select the
connected sensor from the list.
If the baud rate is selected correctly the controller determines all
sensor parameters automatically. When the connection with the
sensor is successful, the LED Connected next to the sensor con-
nection begins to flash.
Repeat the previous steps to define Sensor 2. Return to
the
Data recording
afterwards.
Sensor 1
Sensor selection ILD1700
RS422
Serial number 0707011
Measuring range
20
Reset/default
Data recording
Sensor 1
Sensor 2
Time base
Help
If you use different sensors, input scaling of the sensor measured values and the speci-
fication of the master clock may be necessary, see Chap.
5.3.9.2
, see Chap.
5.3.9.3
. You
reach these parameters in the "Data recording" menu.
Press the button to change to
Time base
. Confirm the
selection with the button .
Edit the parameters.
Cycle selection
= Internal
Operating mode
= Synchronous
The master clock depends on the connected sensors.
Time base
Cycle selection Internal
Master clock kHz 2.500000
Operating m.. Synchronous
Divider cal.. fr..
Divider 2
1
1
D. Programming the calculation module in Block 1
Press the button to change to
Calculation
. Confirm
the selection with the button .
Calculation
Block 1
Block 2
Block 3
Block 4
Block 5
Call the
Block 1
menu with the button . Press the button
to call the
Program selection
menu.
Block 1
Program selection ---
Help
Press the button to select the
Calculation
program.
Press the button twice. This confirms the selection and
you return to the previous menu level.
Program selection
-?- Select
OK
---
-> Calculation<-
Average
Press the button to change to
Data Source 1
. Confirm
the selection with the button .
Press the button to change to
Sensor 1.
Repeat the previous steps to define the
data source 2
.
Input signal is
Sensor 2.
Data source 1
-?- Select
OK
---
-> Sensor 1 <-
Sensor 2
Block 1
Program sel..
Calculation
Data source 1 Sensor 1
Data source 2
Sensor 2
Parameter A 1.000000
Parameter B 1.000000