Page 57
Operation
CSP2008
0
0
0
1 Data preprocessing
0
0
1
0 Data output
0
1
0
0 RS422 sensor input
0
1
0
1 EtherCat input
0
1
1
0 Calculation
Fig. 46 Error coding Error source
D11 ... D4 D3 D2 D1 D0 Error cause
0
0
0
0
0
0
0 no errors
0
0
0
0
0
0
1 Underflow
0
0
0
0
0
1
0 Overflow
0
0
0
0
0
1
1 Unknown
0
0
0
0
1
0
0 Sensor Synchronization
0
0
0
0
1
0
1 RS422 Framing Error
0
0
0
0
1
1
0 RS422 Overflow
0
0
0
0
1
1
1 Undefined sorting or formatting algorithm
0
0
0
1
0
0
0 Unknown error
0
0
0
1
0
0
1
Data not yet valid (occurs if insufficient data are
available for the preprocessing.)
Fig. 47 Error coding Error cause
In the RS422 menu item, you define which results of the calculation blocks will be output
at the interface.
The specification of minimum and maximum measured values or calculation result is still
required as well as output value.
The measured value (calculation result) to be output is automatically scaled for the 16-
bit, i.e. 65536 values, output in the CSP2008.
The digital output value is produced according to the formula:
Digital value =
* 65535
Measured value - Min. output value
Max. output value - Min. output value
Example: Min. Output Value (Measured Value) = -50,
Max. Output Value (Measured Value) = +50, Measured Value = -25;
Digital value =
* 65535 = 16384
-25 - (-50)
50 - (-50)
Values outside the specified limits are output as errors.