<DNPD>
Parameter represents the value of the power expressed in W.
If query is sent, calibrator returns the set value of power using standard exponential format.
Example: 100.60 W is returned as 1.002.
Example:
DC power 1000W:
PDC:POW 1000
Note:
Command switches the calibrator in Power DC mode.
[SOUR]:PDC:VOLT(?) <DNPD>
This command sets the output voltage value in Power DC mode.
<DNPD>
Parameter represents the value of the output voltage expressed in V.
If query is sent, calibrator returns the value of output voltage using standard exponential format.
Example: 110.12 V is returned as 1.002.
Example:
Voltage 230.5V:
PDC:VOLT 230.5
Note:
Command switches the calibrator in Power DC mode.
[SOUR]:PDC:CURR(?) <DNPD>
This command sets the output current value in Power DC mode.
<DNPD>
Parameter represents the value of the output current expressed in A.
If query is sent, calibrator returns the value of output current using standard exponential format.
Example: 11.012 A is returned as 1.001.
Example:
Current 23.05A:
PDC:CURR 23.05
Note:
Command switches the calibrator in Power DC mode.
[SOUR]:PACI:POW(?) <DNPD>
This command sets the power value in Power AC high current mode.