![Meatest M133C Operation Manual Download Page 103](http://html1.mh-extra.com/html/meatest/m133c/m133c_operation-manual_1758454103.webp)
M133C Electric Power/Energy Calibrator
MEATEST
103
Operation manual
Example:
Voltage 23.05V in channel 1:
PIH:CURR1 23.05
Note:
Command switches the calibrator in Power Interharmonic mode.
[SOUR]:PIH:CURR<n>:PHAS(?) <DNPD>
This command sets the phase angle between current output in channel <n> and internal reference
phase.
<DNPD>
Represents the phase angle in degrees.
If query is sent, calibrator returns the set value of the phase angle using standard exponential
format. Example: 156.3
is returned as 1.002.
Example:
PIH:CURR1:PHAS 0
PIH:CURR1:PHAS 120
PIH:CURR1:PHAS 240
Note:
Command switches the calibrator in Power Interharmonic mode.
[SOUR]:PIH:CURR<n>:ENAB(?) <CPD> { ON | OFF }
This command enables (disables) the current output in channel <n>. Disabled outputs are OFF also
during OUTP ON.
ON - enables the output
OFF - disables the output
If query is sent, calibrator returns ON if the output is enabled or OFF if it is disabled.
Example:
PIH:CURR1:ENAB ON
Note:
Command switches the calibrator in Power Interharmonic mode.
[SOUR]:PIH:CURR<n>:IHAR(?) <DNPD>
This command sets the level of interharmonic component for current output in channel <n>.
<DNPD>
Represents the current in A.
If query is sent, calibrator returns the value of output voltage using standard exponential format.
Example: 11.012 V is returned as 1.001.