CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
95-00-00
Page 107
Revision 11
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Table 103. Instrument Troubleshooting (Cont.)
Incorrect reading
Defective indicator
Remove and replace indicator.
Leak in static pressure line
Tighten loose connection. Remove
and replace damaged lines.
Clogged or dirty static port
Clean port and plumbing.
Calibration error
Remove and replace indicator.
Engine Oil Temperature Gauge
Gauge pointer off either end of
scale or fails to respond to
temperature changes
Open or short circuit in gauge
Replace gauge.
Open or short circuit in wiring
harness
Tighten connectors or replace wiring
(Ref. Chap. 96).
Defective sender
Replace sender.
Fuel Quantity Indicating System
Fuel quantity gauge inaccurate,
erratic or inoperative
Wires loose, shorted or open
Check tank sending unit electrical
connections; repair as necessary.
Check electrical wires between tank
sending unit and gauge. Repair as
necessary.
NOTE:
The tank sending unit is potted with sealant (3, Table 201, 91
−
00) to prevent shorting due to moisture ac-
cumulation.
Fuel quantity gauge or sending tank
unit defective
Perform operational check (Ref. Fuel
Quantity Gauge and Tank Sending
Unit Operational Check above).
Replace gauge or tank sending unit.
DC Voltmeter
No reading on voltmeter with
system energized
Power switch at OFF setting
Turn power switch to ON.
Disconnected or damaged electrical
wiring
Reconnect or repair wiring.
Damaged or defective voltmeter
Replace voltmeter.
Needle on voltmeter indicates
maximum voltage
Damaged or defective voltmeter
Replace voltmeter.
Possible short in electrical wiring
Check wiring. Repair as required.
Altimeter
Incorrect reading
Defective indicator
Remove and replace indicator.
Leak in static pressure line
Tighten loose connection. Remove
and replace damaged lines.
Clogged or dirty static port
Clean port and plumbing.
Calibration error
Remove and replace indicator.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......