Table 101. Troubleshooting ICS System (Cont)
Symptom
Corrective Action
Probable Cause
No response when system is
turned on.
Overload has tripped circuit
breaker.
Allow system to cool down
approximately two minutes and
press circuit breaker to ON position.
If circuit breaker trips again, leave
system OFF and troubleshoot and
repair as required. Disconnect ICS
control panel connectors to
determine if trouble is in harness or
ICS control panel.
Defective circuit breaker.
Replace circuit breaker.
Defective circuit or component in
system.
Replace system unit.
System controls not set properly.
Reset controls and check operation.
Intermittent operation during flight.
Loose grounding lead connection.
Check system connectors. Tighten
loose connector.
Loose grounding lead connection.
Tighten connections on ground
studs.
Defective chassis ground.
Repair ground (Ref. Chap. 96 for
electrical repair instructions).
Open or shorted wire in wiring
harness.
Repair wire (Ref. Chap. 96 for
electrical repair instructions).
Broken connector pins.
Repair pin or replace connector.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......