CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
Page 502
Revision 7
95-00-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Table 501. Instrument Cluster Three
−
Pack Calibration Charts
−
369D26415 Unit (Early Model) (Cont)
Step
Remarks
Tolerance
(degrees)
Time
(min)
Ohms
Graduation
Engine Oil Temperature
NOTE:
Use 0
−
750 ohm variable resistor across terminal studs 3 and 8.
1
midrange
139
5
2
15
°
C
734
±
2
Ascending pointer
3
mid range
139
±
3
Ascending pointer
4
125
°
C
46.3
±
2
Ascending pointer
WARNING
Comply with applicable electrical safety precautions when checking ammeter
Ammeter
NOTE:
Connect variable resistor, test ammeter and ammeter to be tested in series with 14.5
±
0.3 Vdc, 2 ampere
power supply. Variable resistor load must provide current range of 0.75
−
1.38 amperes for test. Current flow
of 0.75 amperes through ammeter being tested should show 0.75 ampere on test ammeter.
Step
Graduation
Amperes
Tolerance
Remarks
1
+0.75
+0.75
±
4
2
-75 to -150
-1.38
3
0
0
±
3
NOTE:
Without supply voltage applied to cluster, pointer on each ammeter should return to position at or below
lowest calibration mark on ammeter.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......