CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
Page 204
Revision 11
96-00-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Table 201. Troubleshooting Electrical System (Cont.)
Symptom
Corrective Action
Probable Trouble
Starter
−
generator fails to supply
charging current with engine
operating
Circuit breaker out
Reset circuit breaker.
Reverse current relay defective or
*GCU
Replace reverse current relay or
*GCU.
Excessive discharge rate
Check for cause of excessive
discharge rate.
Charging rate to high
Adjust voltage regulator or *GCU.
Starter
−
generator defective (Check
for sheared armature drive shaft
through air inlet screen)
Replace sheared drive shaft (Refer
to manufacturer ’s publication
−
Ref.
Sec. 01
−
00, Table 201)
Voltage regulator or *GCU
defective
Replace voltage regulator or *GCU.
Voltage regulator or *GCU
incorrectly adjusted
Adjust voltage regulator or *GCU.
Overvoltage relay defective or
*GCU
Replace overvoltage relay or *GCU.
GEN
−
OFF
switch defective
Replace switch.
Defective wiring
Repair or replace defective wiring.
*Defective aft/fwd line contactor
*Replace aft/fwd line contactor.
Ammeter indication off
−
scale below
zero; engine not operating and
GEN
−
OFF switch is on
Defective reverse current relay or
*GCU
Replace reverse current relay or
*GCU.
GEN
−
OUT indicator light on;
voltage lower than normal when
engine is operating
Weak generator field
Replace starter
−
generator.
Defective voltage regulator or
*GCU
Replace voltage regulator or *GCU.
Defective starter
−
generator
Replace or repair starter
−
generator.
Incorrectly adjusted voltage
regulator or *GCU
Adjust voltage regulator or *GCU.
Fluctuating current indication on
ammeter
Unstable voltage regulator or *GCU
Replace voltage regulator or *GCU.
Brushes excessively worn
Replace starter
−
generator brushes.
Defective starter
−
generator
Replace or repair starter
−
generator.
Loose ammeter circuit wiring or
defective resistor R500 if installed
(R500 used with early model
instrument clusters
−
369D S/N
003
−
723 only)
Check ammeter circuit connections
and resistor R500 if installed. Repair
or replace as necessary.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......