Table 201. Troubleshooting Pitot
−
Static System
Symptom
Probable Trouble
Corrective Action
No reading on airspeed indicator
Ice or water in pitot lines or static
pressure tube
Thaw out; clean and dry lines and
tubes.
Erratic readings on airspeed
indicator or altimeter
Leak in pressure lines
Tighten line connections. Replace
connectors or lines if necessary.
Ice or water in pitot lines and static
pressure tube
Thaw out; clean and dry lines and
tube.
Defective interconnecting lines
Check pitot static system using test
set. Repair leaks by tightening
connections and replacing lines as
required.
Pointer of altimeter or airspeed
indicator does not move
Obstruction in pressure source
Clean static and pitot lines.
Defective altimeter or airspeed
indicator
Replace defective indicator.
Disconnected line
Check for disconnected line and
make necessary connections.
Altimeter or airspeed indicator
pointer oscillates
Loose static connections
Tighten static source line
connections.
Moisture in lines
Clear lines.
Defective indicator
Replace defective indicator.
Altimeter pointer will not adjust to
airport altitude within 70 feet (21
meters) on ground with proper
barometer scale setting
Moisture in static pressure lines
Clear static source and
interconnecting lines.
Altimeter instrument case leaking
Replace altimeter.
Barometric scale out of adjustment
Replace altimeter or remove for
adjustment by an authorized
instrument repair agency.
High reading
Improper venting
Clear lines.
Altimeter adjustment knob binds
Defective altimeter
Replace altimeter.
Airspeed indicator pointer does not
align with 0
±
1/16 inch (1.5875
mm) on ground
Defective indicator
Replace indicator.
Moisture in lines
Clear lines.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......