CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
Page 508
Revision 13
95-30-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
12. Digital TOT Indicating System Inspection
(369D/E
−
500N)
Special Tools
(Ref. Section 91
−
00
−
00)
Item
Nomenclature
N/A
Fluke, Model No. 714 tester
N/A
Omega, Model No. CL
−
307A
−
K tester
N/A
Barfield, Model No. TT
−
1000A tester
(1). Disconnect the engine thermocouple
wire harness at the TC300 terminal
block located over the left-hand engine
compartment door.
(2). Connect tester to TC300.
(a). Connect tester wire to #8 stud on
TC300 (white chromel wire)
(yellow lead for Fluke and Omega,
red for Barfield).
(b). Connect tester wire to #10 stud on
TC300 (green alumel wire)
(red lead for Fluke and Omega, black
for Barfield).
For Omega and Fluke testers,
do not force lead into tester, one
lead prong of plug is larger than the other,
damage to tester connection will occur.
(c). Connect lead to tester.
(3). Set power switch to source for Omega
and Fluke or ON position for Barfield.
(4). Set indicator to temperatures in
Table 505.
(5). Turn on aircraft electrical power.
NOTE:
TOT indicator requires approximately
five seconds to reset internal circuitry.
(6). Verify TOT gauge indicates same as
tester, within tolerance (Ref.
Table 505).
(a). If TOT indicator matches tempera
tures in Table 505, no further action
is required.
(b). If TOT indicator does not match
temperatures in Table 505, refer to
applicable Rolls Royce Allison
Operation and Maintenance Manual
for possible maintenance actions.
(7). Turn off aircraft electrical power.
(8). Set source switch to off position.
(9). Disconnect tester from TC300.
(10). Reconnect engine thermocouple wire
harness to TC300 terminal block.
(11). Record compliance to the Service
Bulletin in the Compliance Record
section of the helicopter Log Book.
Table 505. TOT System Test (369D/E
−
500N)
Tester Setting (
°
C)
Indicator Reading (
°
C)
700
°
700
° ±
10
°
725
°
725
° ±
10
°
752
°
752
°
±
10
°
810
°
810
°
±
10
°
CAUTION
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......