CSP-HMI-3
MD Helicopters, Inc
.
MAINTENANCE MANUAL
Page 106
Revision 11
95-00-00
The information disclosed herein is proprietary to MD Helicopters, Inc.
Neither this document nor any part hereof may be reproduced or transferred to
other documents or used or disclosed to others for manufacturing or any other
purpose except as specifically authorized in writing by MD Helicopters, Inc.
Copyright
©
1999
−
2016 by MD Helicopters, Inc.
Table 103. Instrument Troubleshooting
Symptom
Probable Trouble
Corrective Action
Three
−
Pack Indicating System
Engine oil temperature pointer off
either end of scale or does not
respond
Open or short circuit in indicator
Replace instrument cluster.
Open or short circuit in wiring
harness
Replace wiring.
Defective resistor R1
(early instrument cluster only)
Replace defective resistor.
Defective sender
Replace sender.
No reading or erratic ammeter
reading
Malfunctioning voltage regulator
Replace voltage regulator.
Defective resistor R500
(early instrument cluster only)
Replace defective resistor.
Loose connector, open or short
circuit in wiring
Tighten connector or replace wiring.
Dirty or worn mechanism in ammeter
Replace instrument cluster.
Open or short circuit in ammeter
Replace instrument cluster.
NOTE:
The tank sending unit is potted with sealant (CM425) to prevent shorting due to moisture accumulation.
Fuel quantity indicator inaccurate,
erratic or inoperative
Wires loose, shorted or open
Check tank unit electrical
connections; repair as necessary.
Check electrical wires between tank
unit and instrument cluster. Repair as
necessary.
Fuel indicator or tank unit defective
Perform operational check (Ref. Sec.
28
−
00
−
00). Replace instrument
cluster or tank unit.
Defective resistor R1
(early instrument cluster only)
Replace defective resistor.
Ammeter
No reading or erratic reading
Malfunctioning voltage regulator VR1
Replace voltage regulator.
Loose connector, or open or short
circuit in wiring
Tighten connector or replace wiring.
Dirty or worn mechanism in ammeter
Replace ammeter.
Open or short circuit in ammeter
Replace ammeter.
High reading
(369D S/N 003
−
1149)
Excessively high resistance reading
between battery relay and reverse
current relay; 3
−
#10 wires, not to
exceed resistance of 3.64 milliohms
Inspect terminal lugs joining wires,
clean or repair as necessary.
Summary of Contents for 369-500
Page 14: ......
Page 30: ......
Page 82: ......
Page 94: ......
Page 106: ......
Page 116: ......
Page 134: ......
Page 150: ......
Page 162: ......
Page 168: ......
Page 178: ......
Page 226: ......
Page 232: ......
Page 244: ......
Page 346: ......
Page 416: ......
Page 444: ......
Page 458: ......
Page 472: ......
Page 490: ......
Page 536: ......
Page 560: ......
Page 578: ......
Page 604: ......
Page 612: ......
Page 616: ......
Page 628: ......
Page 654: ......
Page 678: ......
Page 706: ......