IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 141
* The SI-EP3 PROFINET option card is limited to F07-23 to F07-27 (DOA115 1 to 6) and F07-33 to F07-37 (DIA166 1 to 5).
5.6 Control I/O Parameters
•
H01 Digital Inputs
•
H02 Digital Outputs
•
H03 Analog Inputs
•
H04 Analog Outputs
•
H05 Serial Communication
•
H06 Pulse Input/Output
5.6.1 Digital Inputs
The VFD has eight multi-function digital inputs for numerous functions. The following table lists the function
selections for Terminals S1 to S8. An OPE03 error will occur if a function is programmed to more than one terminal
at the same time.
Table 5-71: Digital Inputs Parameter Settings
* Initial value is determined by X-Press Programming (
,
).
F07-23 to
F07-32*
DOA116 (1 to 10)
Dynamic parameters that contain the Modbus
addresses used for programmable registers in
the output assembly 116. Data residing in
bites 20 to 39 of assembly 116 will be written
to the respective Modbus registers identified
by the addresses contained in these
parameters. No data is written to the Modbus
registers if the parameter setting is 0.
Modbus Address
0x- - - -
0
F07-33 to
F07-42*
DIA166 (1 to 10)
Dynamic parameters that contain the Modbus
addresses used for programmable registers in
the input assembly 166. Data residing in the
Modbus registers will be written to the
respective assembly 166 bytes 20 to 39. The
Modbus registers are identified by the
addresses contained in these parameters. No
data is written to the programmable registers
if the parameter setting is 0.
Modbus Address
0x- - - -
0
Parameter
Display
Function
Range
Default
H01-01
Term S1 Select
.
0–81
80 (FWD)
H01-02
Term S2 Select
.
0–81
81 (REV)
H01-03
Term S3 Select
.
0–81
*
H01-04
Term S4 Select
.
0–81
*
H01-05
Term S5 Select
.
0–81
*
H01-06
Term S6 Select
.
0–81
*
H01-07
Term S7 Select
.
0–81
*
H01-08
Term S8 Select
.
0–81
*
H01-14
Alt Ref Override
Alternate Frequency Reference Override.
When enabled, and an input of H01-xx = 1F is
ON, will switch between Frequency Reference
Source 2 (B03-15) and the terminals (B01-xx).
0, 1
0
0 Disabled
1 Enabled
Parameter
Display
Function
Range
Default