5.2.9 Electronic Programmable Limit Switches (EPLS)
Using the motor revolutions (U01-51) from the Hook Height Measurement function, it is possible to program UL1,
UL2, LL1, and LL2 positions without the use of rotary limit switches. Hook Height Measurement must be correctly
set up before using EPLS.
Table 5-24: Electronic Programmable Limit Switches Parameter Settings
NOTE:
A setting of 0 disables that specific limit.
Table 5-25: Limit Switch Outputs
Figure 5-10: EPLS Parameter Layout
Parameter
Display
Range
Default
C03-16
UL2 Revolutions
0–65535 Rev
0
C03-17
UL1 Revolutions
0–65535 Rev
0
C03-18
LL1 Revolutions
0–65535 Rev
0
C03-19
LL2 Revolutions
0–65535 Rev
0
H02-0x or F05-0x =
Function
2B - Upper Limit 1
Output ON when keypad displays UL1
2C - Upper Limit 2
Output ON when keypad displays UL2
2D - Lower Limit 1
Output ON when keypad displays LL1
2E - Lower Limit 2
Output ON when keypad displays LL2
30 - Lower Limit
Output ON when keypad displays LL1 or LL2
31 - Up/Low Limit
Output ON when keypad displays UL1, UL2, LL1, or LL2