IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 68
5.1.2 Reference Limits
These parameters limit the frequency range as a percentage of maximum output frequency (E01-04). If the lower
limit is below the DC Inj Start Freq (D01-01), then operation will continue according to B03-05.
An alternate upper limit frequency can be used during operation when a Multi-Function Digital Input (MFDI) is set to
59 (Alt F-Ref Up Lmt) and the MFDI is on.
Table 5-3: Reference Limits Parameter Settings
* Initial value is determined by X-Press Programming (
or
Figure 5-1: Frequency Upper and Lower Limits
Parameter
Display
Function
Range
Default
B02-01
Ref Upper Limit
Percentage of the maximum output
frequency (E01-04), which determines the
maximum frequency at which the VFD is
able to run.
0.0–110.0%
100.0*
B02-02
Ref Lower Limit
Frequency reference lower limit as a
percentage of maximum output frequency
(E01-04).
0.0–110.0%
0.0
B02-03
Ref1
Lower Limit
Frequency reference lower limit, from
analog inputs, as a percentage of
maximum output frequency (E01-04).
0.0–110.0%
2.0*
B02-04
Alt Upper Limit
Alternate of B02-01 set by MFDI=59.
0.0–110.0%
0.0