EMC Filters
Install the VFD with the EMC filters listed in
through
requirements. Schaffner filters are supplied in North America, and Block filters are supplied in Europe.
Table B-1: IEC/EN61800-3 Filters (Manufacturer: Schaffner) – 230 V Class
VFD Model
Filter Data (Manufacturer: Schaffner)
Schaffner Type
Rated
Current
(A)
Weight
lb (kg)
Dimensions
W x D x H (in)
[W x D x H (mm)]
Mounting
Dimensions
Y x X (in)
[Y x X (mm)]
Figure
2003
FS5972-10-07
10
2.6 (1.2)
5.6 x 1.8 x 13.0
(141 x 330 x 46)
4.5 x 12.3
(115 x 313)
2005
2007
2008
FS5972-18-07
18
2.9 (1.3)
5.6 x 1.8 x 13.0
(141 x 330 x 46)
4.5 x 12.3
(115 x 313)
2011
2014
FS5972-35-07
35
4.6 (2.1)
8.1 x 2.0 x 14.0
(206 x 355 x 50)
6.9 x 15.4
(175 x 336)
2017
2025
2033
FS5972-60-7
60
8.8 (4.0)
9.3 x 2.6 x 16.1
(236 x 408 x 65)
8.1 x 15.4
(205 x 390)
2047
2060
FS5972-100-35
100
7.5 (3.4)
3.5 x 5.9 x 13.0
(90 x 330 x 150)
2.6 x 10.0
(65 x 255)
2075
2085
FS5972-170-40
170
13.2 (6.0)
4.7 x 6.7 x 17.8
(120 x 451 x 170)
4.0 x 14.4
(102 x 365)
2115
2145
FS5972-250-37
250
25.8 (11.7)
5.1 x 9.5 x 24.0
(130 x 610 x 240)
3.5 x 19.6
(90 x 498)
2180
2215
FS5972-4100-99
410
23.1 (10.5)
10.2 x 4.5 x 15.2
(260 x 386 x 115)
9.3 x 4.7
(235 x 120)
2283
2346
FS5972-600-99
600
24.3 (11)
10.2 x 5.3 x 15.2
(260 x 386 x 135)
9.3 x 4.7
(235 x 120)
2415