IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 66
5 Programming Advanced Features
5.1 Speed Parameters
The speed parameters control the speed frequencies, acceleration and deceleration characteristics, and reference
sources. Speed parameters included in this section are listed below:
•
B01 Speed References
•
B02 Reference Limits
•
B03 Run/Reference Source
•
B05 Acceleration/Deceleration
•
B08 Jump Frequencies
•
B09 Field Forcing
5.1.1 Speed References
Table 5-1: Speed Reference Parameter Settings
* Initial value is determined by X-Press Programming (
Parameter
Display
Function
Range
Default
B01-01
Reference 1
Speed 1 frequency
0.00–E01-04 Hz
15.00*
B01-02
Reference 2
Speed 2 frequency
0.00–E01-04 Hz
30.00*
B01-03
Reference 3
Speed 3 frequency
0.00–E01-04 Hz
60.00*
B01-04
Reference 4
Speed 4 frequency
0.00–E01-04 Hz
0.00*
B01-05
Reference 5
Speed 5 frequency
0.00–E01-04 Hz
0.00*
B01-06
Reference 6
Speed 6 frequency
0.00–E01-04 Hz
0.00*
B01-07
Reference 7
Speed 7 frequency
0.00–E01-04 Hz
0.00*
B01-08
Reference 8
Speed 8 frequency
0.00–E01-04 Hz
0.00*
B01-09
Reference 9
Speed 9 frequency
0.00–E01-04 Hz
0.00*
B01-10
Reference 10
Speed 10 frequency
0.00–E01-04 Hz
0.00*
B01-11
Reference 11
Speed 11 frequency
0.00–E01-04 Hz
0.00*
B01-12
Reference 12
Speed 12 frequency
0.00–E01-04 Hz
0.00*
B01-13
Reference 13
Speed 13 frequency
0.00–E01-04 Hz
0.00*
B01-14
Reference 14
Speed 14 frequency
0.00–E01-04 Hz
0.00*
B01-15
Reference 15
Speed 15 frequency
0.00–E01-04 Hz
0.00*
B01-16
Reference 16
Speed 16 frequency
0.00–E01-04 Hz
0.00*
B01-17
Jog Reference
Jog Control and Inching Control frequency
0.00–E01-04 Hz
6.00*
B01-18
Ref Priority
0 Digital Ref Only
1 Analog Ref Only
2 Higher RefSelect
Determines whether the digital or analog
frequency reference is used.
NOTE:
When
using Higher Reference Select, Infinitely
Variable should NOT be used (A01-04 = 3).
The two functions are not intended to work
in conjunction.
0–2
0*