IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 62
4.3.3.9
User Parameters (A02-01 through 32)
The user can select up to 32 parameters for quick-access programming. By setting the user access level (
A01-01
)
to “User Program”, only the parameters selected in the A02 parameters can be accessed by the user. To assign a
parameter as a user parameter, go to the A02 level in the initialize menu. Once the A02 parameters are set and
A01-01
is programmed to “User Program”, only the parameters visible in the program menu will be assigned to an
A02 parameter.
The A02 group is pre-loaded with the settings listed in
, based on A01-03.
Table 4-10: Application Quick Set
A01-03
0
1
2
Parameter
Traverse
Std Hoist
NLB Hoist
-
B01-01: Speed 1
B01-01: Speed 1
B01-01: Speed 1
A02-01
B01-02: Speed 2
B01-02: Speed 2
B01-02: Speed 2
A02-02
B01-03: Speed 3
B01-03: Speed 3
B01-03: Speed 3
A02-03
B01-04: Speed 4
B01-04: Speed 4
B01-04: Speed 4
A02-04
B01-05: Speed 5
B01-05: Speed 5
B01-05: Speed 5
A02-05
B03-04: Change Rotation
B03-04: Change Rotation
B03-04: Change Rotation
A02-06
B05-01: Accel Time 1
B05-01: Accel Time 1
B05-01: Accel Time 1
A02-07
B05-02: Decel Time 1
B05-02: Decel Time 1
B05-02: Decel Time 1
A02-08
C01-03: Reverse Plug
C02-01: MicroSpd Gain 1
C01-01: Quick Stop
A02-09
C01-04: Rev-Plg Dec Time
C03-01: UL1 Speed
C01-02: Quick Stop Time
A02-10
C01-05: Rev-Plg Acc Time
C03-04: LL1 Speed
C02-01: MicroSpd Gain 1
A02-11
C02-01: MicroSpd Gain 1
C06-01: Swift-Lift
C03-01: UL1 Speed
A02-12
E01-03: V/f Selection
C06-02: SwiftLift FWDSpd
C03-04: LL1 Speed
A02-13
E02-01: Motor Rated FLA
C06-03: SwiftLift REVSpd
C06-01: Ultra-Lift
A02-14
H01-06: Terminal S6
C06-04: SL FWD Current/Torque
C06-02: UltraLift FWDSpd
A02-15
H01-07: Terminal S7
C06-05: SL REV Current/Torque
C06-03: UltraLift REVSpd
A02-16
H01-08: Terminal S8
C06-06: SL Enabling Spd
C06-04: UL FWD Torque
A02-17
H02-03: Terminal M5/M6
E01-03: V/F Selection
C06-05: UL REV Torque
A02-18
H03-02: Terminal A1
E01-04: Max Frequency
C08-03: Min Brk Rel Trq
A02-19
H04-02: Terminal FM Gain
E02-01: Motor Rated FLA
C08-10: Load Float Time
A02-20
-
H01-06: Terminal S6
C08-11: Brake Set Delay
A02-21
-
H01-07: Terminal S7
C08-14: Brake Hold Speed
A02-22
-
H01-08: Terminal S8
F01-01: PG1 Pulses/Rev
A02-23
-
H02-03: Terminal M5/M6
F01-05: PG1 #Gear Teeth2
A02-24
-
H03-02: Terminal A1
H01-06: Terminal S6
A02-25
-
H04-02: Terminal FM Gain
H01-07: Terminal S7
A02-26
-
-
H01-08: Terminal S8
A02-27
-
-
H02-03: Terminal M5/M6
A02-28
-
-
H03-02: Terminal A1
A02-29
-
-
H04-02: Terminal FM Gain
A02-30
-
-
-
A02-31
-
-
-
A02-32
-
-
-