5.2.1 Quick Stop™
Quick Stop
provides an automatic Alternate Deceleration at Stop.
NOTE:
The Quick Stop Deceleration time differs from the normal deceleration time and is applied only when the
RUN command is removed.
Table 5-15: Quick Stop Parameter Settings
* Initial value is determined by X-Press Programming (
or
Figure 5-7: Quick Stop
Parameter
Display
Function
Range
Default
C01-01
Quick Stop
Determines whether Quick Stop is enabled
0, 1
0*
0 Disabled
1 Enabled
C01-02
Quick Stop Time
Deceleration time during Quick Stop function.
0.0–25.5 sec
1.0