IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 153
Table 5-82: Selections for H03-02, H03-06, and H03-10 (Flux Vector)
Display
Function
0 Analog Freq Ref1
Analog Frequency reference 1
10V = E01-04 (Maximum output frequency)
1 Frequency Gain
Analog frequency reference will be multiplied with the analog frequency reference gain.
2 Analog Freq Ref2
Analog Frequency reference 2
10V = E01-04 (Maximum output frequency)
3 Analog Freq Ref3
Analog Frequency reference 3
10V = E01-04 (Maximum output frequency)
5 Acc/Dec T Reduct
10V = 100% acceleration and deceleration time
7 OT / UT Det Lvl
Overtorque/undertorque level as a percentage of motor rated torque.
9 Ref Lower Limit
Max. output frequency
10V = E01-04 (Maximum output frequency)
D Freq Ref Bias 2
The input value of an analog input set to this function will be added to the frequency reference.
This function can be used with any frequency reference source.
E MotorTemperature
PTC thermistor input. Set DIP switch S4 to “PTC.”
10 FWD Torque Limit
Torque limit when motoring in the forward direction.
11 REV Torque Limit
Torque limit when motoring in the reverse direction.
12 Regen Torque Limit
Torque limit during regen.
13 Torque Reference
Torque reference when in Torque Control mode; Torque limit when in Speed Control mode.
14 Torque Comp
Torque compensation when using torque control.
15 Torque Limit
Torque limit when motoring.
16 Load Cell
Used for Weight Measurement
1F Not Used
-