IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 222
C06-03
SwiftLift REVSpd (V/f and OLV)
UltraLift REVSpd (FLV)
60.0
0.1–150.0
Hz
C06-04
SL FWD Current (V/f)
SL FWD Torque (OLV)
UL FWD Torque (FLV)
50
0–100
%
C06-05
SL REV Current (V/f)
SL REV Torque (OLV)
UL REV Torque (FLV)
30
0–100
%
C06-06
SL Enabling Spd (V/f and OLV)
UL Enabling Spd (FLV)
59.0
0.0–150.0
Hz
C06-07
SL Delay Time (V/f and OLV)
UL Delay Time (FLV)
2.0
0.0–25.5
sec
C06-08
SFS Acc Gain
1.0
0.1–9.9
-
C06-10
Mtr Trq Quickset
3
0–5
-
C06-11
Motor Torque 1
45
1–100
%
C06-12
Motor Speed 1
150
100–300
%
C06-13
Motor Torque 2
25
1–100
%
C06-14
Motor Speed 2
200
100–300
%
C06-15
AUL FWD Offset
10
0–100
%
C06-16
AUL REV Offset
20
0–100
%
C07-01
Torque Limit FWD
150
0–300
%
C07-02
Torque Limit REV
150
0–300
%
C07-03
Torque Limit FWD Regen
180
0–300
%
C07-04
Torque Limit REV Regen
180
0–300
%
C07-05
Torque Limit FWD Gain
1.25
0.00–2.55
-
C07-06
Torque Limit REV Gain
1.25
0.00–2.55
-
C07-07
Torque Limit Regen Gain
1.25
0.00–2.55
-
C07-08
Torque Limit I Time
200
5–10000
ms
C07-09
Torque Limit Sel
0
0, 1
-
C07-10
Traverse Torque Limiter
0
0, 1
-
C07-11
Limiter Freq
2.0
0.5–10.0
Hz
C07-12
Anti-Shock
0
0–2
-
C07-13
Enabling Freq
6.0
0.0–60.0
Hz
C07-14
Re-Accel Delay
0.20
0.00–2.55
sec
C07-15
Torque Delta
10
0–180
%
C07-16
Detection Time
0.30
0.01–0.50
sec
C07-17
Smoothing Freq
3.0
0.0–15.0
Hz
C07-18
Smoothing Decel
0.30
0.00–1.00
sec
C07-20
Smoothing Time
1.00
0.00–2.55
sec
C07-22
AlarmDisplayTime
4
0–30
sec
C07-23
No Load Torque
20
0–100
%
C07-24
Required Torque
75
0–180
%
C07-25
Detection Method
1
0–2
-
C08-01
Torque Comp Time
1.00
0.00–2.55
sec
Parameter
Parameter Name
Default
Range
Units
Reference