IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 156
H04-01
606 Voltage Ref (Vd)
000–630
102
607 ACR(q) Output
608 ACR(d) Output
611 Iq Reference
612 Id Reference
618 PG1 CounterValue
619 PG2 CounterValue
622 Zero Servo Pulse
625 ASR Out w/o Fil
626 FF Cont Output
627 FF Estimate SPD
H04-02
Terminal FM Gain
Gain multiplier for Terminal FM
-999.9–999.9%
100.0
H04-03
Terminal FM Bias
Bias multiplier for Terminal FM
-999.9–999.9%
0.0
H04-04
Terminal AM Sel
Function selection for analog output
Terminal AM
000–630
103
H04-05
Terminal AM Gain
Gain multiplier for Terminal AM
-999.9–999.9%
50.0
H04-06
Terminal AM Bias
Bias multiplier for Terminal AM
-999.9–999.9%
0.0
H04-07
FM Level Select
Voltage output level of Terminal FM
0–2
0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA
H04-08
AM Level Select
Voltage output level of Terminal AM
0–2
0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA
Only available on 24 VDC interface board
Parameter
Display
Function
Range
Default