U01-60
PG CH1 Count
Raw PG Channel 1 pulse count
4 pulses = 1 ppr of F01-01
Pulses
U01-61
PG CH2 Count
Raw PG Channel 2 pulse count
4 pulses = 1 ppr of F01-01
Pulses
U01-63
PG CH1 Freq
Input frequency on PG Channel 1
Hz
U01-64
PG CH2 Freq
Input frequency on PG Channel 2
Hz
U01-65
PG Output Freq
Output frequency on the PG Output channel
Hz
U01-66
BE6 Pulse Count
Amount of shaft movement during the BE6 detection time
4 pulses = 1 ppr of F01-01
Pulses
U01-68
LC Zone
LC Zone the VFD is currently running in. If an LC fault occurs, the
value displayed will be which LC zone the LC fault occurred in.
-
U01-69
LC Margin
How close the current/torque levels are to the target value for each
of the LC zones. Values less than zero will cause an LC detection or
an LC fault to occur. If the LC fault occurs, the value displayed is the
amount the level was below the LC zone setting.
%
U01-84
NLB State
Current NLB State Machine sequence.
Analog Output Level: 0.5V/State
-
U01-85
NLB Rel Trq
Torque level for next BE2 check. Is set to 100% after BE2 is passed,
and set to torque output level at end of Load Float. No signal output
available
%
U01-86
Brk Test Trq
Brake breakaway torque; FLV only; MFDI needs to be programmed
with “Brake Test”