5.1.9 Acceleration/Deceleration
Acceleration time sets the time necessary for the output frequency to accelerate from 0 Hz to maximum output
frequency (E01-04). Deceleration time sets the time necessary for the output frequency to decelerate from the
maximum output frequency (E01-04) to 0 Hz.
Table 5-10: Acceleration/Deceleration Parameter Settings
* Initial value is determined by X-Press Programming (
or
** Range is extended to 0.0–6000.00 when B05-16 = 1.
Figure 5-5: Normal Accel/Decel Time and Multiple Accel/Decel Changeover
NOTE:
Assume B03-03 is set to “0” (Decel to Stop).
Parameter
Display
Function
Range
Default
B05-01
Accel Time 1
Sets acceleration time
0.0–25.5 sec**
5.0*
B05-02
Decel Time 1
Sets deceleration time.
0.0–25.5 sec**
3.0*
B05-03
Accel Time 2
Acceleration time 2 enabled when H01-xx = 1A.
0.0–25.5 sec**
10.0
B05-04
Decel Time 2
Deceleration time 2 enabled when H01-xx = 1A.
0.0–25.5 sec**
10.0